Section 3 — Config Parameters
3 Source Config
o0
00 — 3 Source Config
The 3 Source Config divides the DP/4+ into 3 effects processors. Units A and B function
independently as 1 Unit processors, while C and D are grouped together as a single 2 Unit effects
processor.
o1
01 — CD Input Select
This parameter selects either a mono (Input 3) or stereo (Inputs 3 and 4) signal for Units C and D.
o2
02 — CD Unit Routing
Units C and D can be routed together in one of four different ways, as explained earlier in the 1
Source Config parameters.
o3
03 — (Config Dependent)
This parameter is dependent on how Units C and D are routed. See the description about config
dependent parameters under 1 Source Config (parameters 05 and 06) for more information.
12
3 Source Config
1>A 2>B 3,4 >CD
CD Input Select
(3,4) Stereo
Range:
(3,4) Stereo or (4) Mono
CD Unit Routing=
[C®D] feedback1
Range:
serial, parallel, feedback1, or feedback2
Dry Path Around
CD Amt =00