ZyXEL Communications P-660R-Tx v3 Series Support Notes page 33

Hide thumbs Also See for P-660R-Tx v3 Series:
Table of Contents

Advertisement

P-660R-Tx v3 Series Support Notes
1
Since SUA enables your LAN to appear as a single computer to the Internet,
it is not possible to configure similar servers on the same LAN behind SUA.
2
Because White Pine Cu-SeeMe uses dedicate ports (port 7648 & port 24032)
to transmit and receive data, therefore only one local Cu-SeeMe is allowed
within the same LAN.
Configurations
For example, if the workstation operating Cu-SeeMe has an IP of 192.168.1.33,
then the default SUA server must be set to 192.168.1.33. The peer Cu-SeeMe
user can reach this workstation by using P-660R-Tx v3's WAN IP address
which can be obtained from Web Configurator, Status -> Device Info
->WAN.
33
All contents copyright © 2008 ZyXEL Communications Corporation.

Advertisement

Table of Contents
loading

Table of Contents