Delta Elec. Inc.
< Powering up >
Power: Flashing Green
< Normal operation >
Yes
Power: Light Green
< System error >
Power: Blink 4 (Green)
Lamp: OFF
Temp: OFF
No
< Lamp Error >
Power: Flashing 0.5Sec (Green)
Lamp: Steady Light (Red)
Temp: OFF
No
Company Confidential
18
Turn the
power ON
Lamp: OFF
Temp: OFF
Lamp: OFF
Temp: OFF
Optoma__________________
EH1060
Yes
• Lamp Cover A'ssy is not attached
• Thermal break sensor is open.
• Connector (CN11) on Keypad Board disconnected.
Yes
System Change a new Lamp
Delta________________
2010/03/17