Example 2
Example 2 illustrates a more complicated setup and demonstrates several scenarios for configuring VLANs.
1.  Set up four VLANs, as shown in following table.
All switch ports remain as members of the default VLAN (VLAN
ID 1).
VLAN ID Name
Port Members (Tagged/Untagged)
2
Admin
1 (U), 2 (U), 10 (U)
5
Internal
1 (U), 4 (U), 5 (U)
10
W e b
1 (T), 9 (T), 10 (T), 11 (U), 12 (U)
15
Collocation 1 (U), 2 (U), 14 (U)
2.  Set up the Port VLAN IDs (PVIDs), as shown in the following figure:
The specific ports shown in the previous figure have the following PVID settings. The PVID settings for each port are configured in the Port Settings
page.