SECTION5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This
check
verifies
proper
operation
of the valve
motor,
brine
tank fill, brine
draw, regeneration
flow
rates,
and other
controller
functions.
Always
make
the initial
checks,
and the manual
initiated
diag-
nostics.
Note:
If water
system
pressure
is low, an elevated
drain
hose may cause back pressure,
stopping
brine draw.
[]
Again
press
RECHARGE
to move
the softener
into backwash.
Look for a fast flow of water
from
the drain
hose.
Notes:
The faceplate
display
must
show a steady
time (not
flashing).
If an error
code shows,
first press
the SE-
LECT button
to enter
the diagnostic
display.
Press
RECHARGE
button
hold in
the
and
for 3
seconds.
RECHARGE
NOWbeglns
to flash in the
display
as the softener
enters
the fill cycle of re-
generation.
Remove
the brinewell
cover and, us-
ing a flashlight,
observe
fill water
entering
the
tank.
a. An obstructed
flow indicates
a plugged
top dis-
tributor,
backwash
flow plug,
or drain
hose.
Press RECHARGE
to move the softener
into fast
rinse. Again
look for a fast drain
flow. Allow
the
softener
to rinse
for a few minutes
to flush
out
any brine
that may remain
in the resin tank from
the brining
cycle test.
'Ib return
the
softener
to service,
press
RE-
CHARGE.
a. If water
does
not enter
the tank,
look for an ob-
structed
nozzle,
venturi,
fill flow plug, brine tubing,
or brine
valve
riser pipe.
CYCLE FLOW RATES (GALLONS
PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
_
.15 (.57 liters)
BRINE RINSE
I
(flow
.1 (.38 liters)
to
2.2 (8.3 liters)
MAX. BACKWASH
drain)
MAX. FAST RINSE
2.2 (8.3 liters)
After observing
fill, press
the RECHARGE
but-
ton to move
the softener
into brining.
A slow
flow of water
to the drain
will begin.
Verify brine
draw
from the brine
tank by shining
a flashlight
into
the brinewell
and
observing
a noticeable
drop
in the liquid
level.
Note:
Be sure a salt bridge
is not preventing
water
with
salt contact.
a. If the softener
does not draw
brine...
...nozzle
and/or
venturi
dirty
or defective.
...nozzle
and venturi
not seated
properly
on gasket.
...restricted
drain
(check
drain
fitting
and hose).
...defective
nozzle
and venturi
seal.
...other
inner
vane
defect
(rotor
seal
rotor
& disc,
wave
washer,
etc.).
17
BRINE VALVE
'
FLOAT _ETTING
_
float stop
FREEBOARD
MEASUREMENT
(Distance from top of resin tank, to top of resin bed.)
5-4
Problems,
Questions?
Call 1-800-426-9345