4) Undo the right hand screw on the cable
clip. (Fig. 6)
fig. 6
5) Disconnect the electrical connector by
pushing the tabs B, then pulling out the
connector (fig. 7)
2
fig. 7
6) Remove the safety plug (fig. 8).
fig. 8
7) Open the locking lever on the quick-fit
coupling. To facilitate closing, use the
extension
24
, fitting it onto the lever and
turning until fully open (see figure 9).
22
Pre p a r i n g f o r u s e
B
1
fig. 9
8) Disconnect the male and female cou-
plings by pushing the sleeve backwards
and pulling (Fig. 10).
1
2
To avoid damage to the couplings, before
passing the sheath through the hole in the
wall, you should protect the ends of the
quick-fit coupling using the caps provided or
with paper tape (Fig. 11).
fig. 11
Make sure the connecting sheath is free of
kinks.
Important
Always disconnect or connect the quick-fit
couplings in the open air or adequately ven-
tilated rooms.
fig. 10