Specifications

Power:
120 V AC units: 60 Hz, Current 60 mA max.
Sensor:
Sensor calibrated at 150 ppm (±25 ppm).
Temperature:
Operating range: 4.4˚C (40˚F) to 37.8˚C (100˚F).
Humidity:
Operating range: 5–95% non-condensing.
Mounting:
Accessories supplied for wall mount, direct plug and tabletop
applications.
Alarm:
85+ dB at 3 m (10') @ 3.4 ± 0.5 KHz pulsing alarm.
CO Alarm Time:
At 70 PPM, the unit must alarm within 60–240 minutes.
At 150 PPM, the unit must alarm within 10–50 minutes.
At 400 PPM, the unit must alarm within 4–15 minutes.
Digital Display Accuracy:
Each Kidde CO Alarm is calibrated at a CO concentration
of 150 ppm in air, at 80˚ F (+/- 10˚ F). Depending on the
ambient condition (temperature, humidity) and the
condition of the sensor, the alarm readings may vary.
The digital reading tolerances are:
Ambient: 80˚ F (+/- 10˚ F), atmospheric pressure +/- 10%,
40% +/- 3% relative humidity.
Reading
0-999 ppm
Depending on the ambient condition (temperature,
humidity) and the condition of the sensor, the alarm
readings may vary.
28
Tolerance
(of displayed reading)
+/-20% +15 ppm