Description of Parts

Solenoid Valve
All brass construction, controls the flow of water to the humidifier. The solenoid
valve will make a clicking sound as the plunger pin opens and closes. If this part
fails to operate correctly, water will flow continuously through the humidifier and
down the drain.
Conical Mesh Filter
Traps small particles in water supply that can clog and damage the solenoid valve.
Must be cleaned or replaced when water flow is impeded or humidification is
reduced.
Evaporator Pad
Allows water to evaporate as warm, dry air is drawn through it. Must be replaced
on a regular basis to maintain efficiency.
Fluid Restrictor
Located within the water tubing of the humidifier, it controls the amount of water
that flows through the humidifier.
Side Panels
Plastic construction and right or left hand discharge allows the unit to be installed
in a variety of installations. 1" wide collar allows for more secure installation of
bypass duct.
Water Distribution Tray
Felt wicking allows even distribution of water across surface of evaporator pad. As
mineral deposits build up, the tray will effectively channel the water through the
evaporator pad. Holes in tray must be cleaned periodically.