Specifications - Friedrich MW09Y3FM Service Manual

Inverter multi air conditioner wall mounted type refrigerant r410a
Hide thumbs Also See for MW09Y3FM:
Table of Contents

Advertisement

SPECI F IC AT I O NS
(O UT D OO R U NI T)
ELECTRICAL DATA
TYPE
MODEL NAME
POWER SUPPLY
FREQUENCY
AIR CIRCULATION - High
NOISE LEVEL
COMPRESSOR
TYPE
DISCRIMINATION
REFRIGERANT
FAN MOTOR
DISCRIMINATION
HIGH-SPEED
REFRIGERANT CHARGE (R410A)
ADDITIONAL
CHARGE
ADDITIONAL CHARGE
CHARGELESS
MAX PIPE LENGTH (each unit)
MAX PIPE LENGTH (total)
MAX ELEVATION (between indoor units)
MAX ELEVATION (between indoor and outdoor units)
MIN. PIPE LENGTH (each unit)
MEASUREMENT
DIMENSIONS
WEIGHT
2006.04.25
Cooling
Heating
Cooling
Heating
Cooling
Heating
Total Pipe Length
164 ft (50.0 m)
197 ft (60.0 m)
230 ft (70.0 m)
H x W x D
Net / Gross
4 room multi inverter
MR36TQY3F
230 / 208 V
60 Hz
2119 cfm (3,600 m
2237 cfm (3,800 m
51 dB
53 dB
Hermetic type, Inverter, 4 poles,
3-phase, DC motor, Twin Rotary
TNB220FPBM9
R410A
7 lb 7/8 oz (3,200 g)
MFE-45ROM
850 r.p.m.
900 r.p.m.
-- (Chargeless)
8-13/16 oz (250 g)
1 lb 1-5/8 oz (500 g)
9/32 oz/ft (25 g/m)
164 ft (50 m)
82 ft (25 m)
229 ft (70 m)
49 ft (15 m)
49 ft (15 m)
16 ft (5 m)
32-7/8 x 35-7/16 x 13 inch
(835 x 900 x 330 mm)
149 lb / 167 lb (68 kg / 76 kg)
2
3
/hr)
3
/hr)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mw12y3fmMr36tqy3fMw18y3fm