Customer Responsibilities
Check Safety Valve
Drain Tank
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
NOTE: See Operation section for the
location of controls.
To Check Safety Valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.

MAINTENANCE

Before
each
use
Risk of Unsafe
Operation. Unit
Risk of Bursting.
If the safety valve
Daily
or after
each
use
To Drain Tank
1.
Set the On/Auto/Off lever to
"Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise.
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
15 - ENG
Risk of Bursting.
Water will
1000001251