Electrical Requirements - Kenmore 790.3690 Installation Instructions Manual

30" gas slide-in range
Hide thumbs Also See for 790.3690:
Table of Contents

Advertisement

Available languages

Available languages

Assemble the flexible connector fromthe gassupply pipe
to the pressure r egulator i nthefollowingorder:
1. manual shutoffvalve(notincluded)
2. 1/2" nipple(notincluded)
3. 1/2"flareunionadapter(notincluded)
4. flexibleconnector ( notincluded)
5. 1/2"flareunionadapter(notincluded)
6. 1/2" nipple(notincluded)
7. pressure r egulator(included)
Usepipe-joint c ompound m ade for usewith Natural a nd
LP/Propane gasto seal a llgasconnections. If flexible
connectors areused, b ecertain connectors a renot
kinked.
Thesupply linemustbeequipped w ith anapproved
manual s hutoff v alve. T his valve should belocated in
thesame roomasthe range andshould bein a location
thatallows ease of opening andclosing. Donot block
access to the shutoffvalve. T hevalveisfor turningon or
shutting off gasto the appliance.
t_
|
LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
If you wish to convert your range for use with LP/
Propane gas, use the supplied fixed orifices located in a
bag containing the literature marked "FOR LP/PROPANE
GAS CONVERSION." Follow the instructions packaged
with the orifices for surface, oven and broil burners
conversion.
The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Shutoff Valve -
Open position
Figure 4
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.
Check for leaks, After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector (or soap and water) at all joints
and connections to check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
Tighten
all connections
as necessary to prevent gas
leakage in the range or supply line.
Disconnect
this range and its individual manual
shutoff
valve from the gas supply piping system during
any pressure testing of that system at test pressures
greater than 1/2 psig (3.5 kPa or 14" water column).
Isolate the range from the gas supply piping
system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa or 14"
water column).
|
Electrical
Requirements
120 volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15 amp circuit breaker or time delay fuse.
Note: Not recommended to be installed with a Ground
Fault Interrupt (GFI).
Do not use an extension
cord with this range.
Grounding
Instructions
IMPORTANT Please read carefully.
For personal
safety, this appliance
must be properly
grounded,
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle (see Figure 5) to
minimize the possibility of electric shock hazard from the
appliance.
The wall receptacle and circuit should be checked by
a qualified electrician to make sure the receptacle is
properly grounded.
Preferred Method
Grounding type
wall receptacl
Do not, under any
circumstances,
cut,
remove, or bypass
the grounding
prong.
Power supply cord with
3-prong grounding plug.
Figure 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

790.3693

Table of Contents