Connectors - Axis M1054 User Manual

Hide thumbs Also See for M1054:
Table of Contents

Advertisement

AXIS M1054 Network Camera
Technical Specifications
Item
Function/group
Weight
Included
accessories
Video
management
software (not
included)
Optional
accessories

Connectors

I/O terminal connector
4–pin terminal block for:
• Digital Input
• Digital Output
• Auxiliary power and ground (GND)
Function
GND
3.3 V DC Power
Digital Input
Digital Output
Specifications
Camera: 0.2kg (0.3 lb.)
Power supply, stand and clamp, Installation Guide, CD with installation tools, recording
software and User Manual, Windows decoder 1-user license, extension for stand: 100
mm [4.0"]
AXIS Camera Station — Video management software for viewing and recording up to 50
cameras
See www.axis.com/products/video/software/ for more software applications via partners
AXIS T8412 Installation Display, AXIS Mobile Monitor
Pin
Notes
1
Ground
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to GND to activate, or leave floating (unconnected)
to deactivate.
4
Internal connection to ground when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
54
Specifications
Max load = 50 mA
0 to +40 V DC
Max load =100 mA
Max voltage = +40 V DC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents