TEST AND ADJUSTMENT

❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
NOTE: Meets the ENERGY STAR
D
B
function is off and ON-TIME is 1 or 5 mi-
®
ual
rite
nutes.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), D
and the ON-TIME control to the TEST position.
NORMAL SOFT FLASH
ON-TIME
MIN
MAX
TEST 1 5 20
RANGE
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or unwanted traffic may trigger
the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range
/
minute warm up period
1
2
guidelines when
®
B
to OFF,
®
ual
rite
LAMP MODE
DUAL BRITE™
OFF 3 6 DUSK TO
MINUTES
HOUR
DAWN
100 ft.
(30.5 m)
Boosted
Maximum
Coverage Angle
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
Least Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 2" (51 mm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the D
ual
after dusk you want the lights on at low level (Off,
270°
3, 6 Hrs., Dusk-to-Dawn).
❒ Set the LAMP MODE switch to the desired light
turn-on effect (Normal, Soft, Flash).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
4
Motion
Sensor
Most Sensitive
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
B
®
switch to the amount of time
rite
Clamp
Screw
Ball
Joint
598-1315-02