Test And Adjustment; Specifications - Heath Zenith DUAL BRITE SL-5597 User Manual

Motion sensor light control for canadian tire
Hide thumbs Also See for DUAL BRITE SL-5597:
Table of Contents

Advertisement

Available languages

Available languages

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on or when switching modes wait 1
Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the
TEST position.
MAX
ON - TIME
MIN
TEST 1 5 2 0
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the sensor at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m) (30.5 m)
Maximum
Range
The control is most sensitive to motion across it.
Motion
Least Sensitive
598-1038-03
1
/
minute warm up period
2
1
/
minutes.
2
DUAL BRITE
OFF 3 6 DUSK TO
HOUR DAWN
100 ft.
Boosted
Maximum
Coverage Angle
Motion
Sensor
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently ro-
tate the sensor.
❒ Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area.
Keep the sensor at least 2"
(51 mm) away from the lamps.
❒ Adjust the RANGE as needed.
Too much range may increase
false triggering. Range Boost
increases coverage up to 100
feet.
❒ Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 20 minutes).
❒ Set the DUAL BRITE™ switch to the amount of time
after dusk you want the lights on at low level (Off, 3,
6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m); 100
Sensing Angle . . . . . . . . Up to 240°
Electrical Load . . . . . . . . Up to 200 Watts Maximum
240°
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . . 1 , 5, 20 minutes
Dual Brite™ Timer . . . . . 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . . T4 100W, G8 halogen bi-pin
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
ft.(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Incandescent (Up to 100
Watts Maximum each lamp
holder.)
MODE
120 VAC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents