Hunter Model Type 2 Owners And Installation Manual

Model type 2 hunter ceiling fan

Advertisement

For Your Records and
Warranty Assistance
For reference, also attach your receipt or a copy
of your receipt to the manual.
Talon
__________________________________________
Model Name
20731
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
Form# 45034-01
20081023
©2008 Hunter Fan Co.
Model Type 2
Model Type 2
Model Type 2
Owner's Guide and Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hunter Model Type 2

  • Page 1 Model Type 2 Model Type 2 Model Type 2 For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Owner’s Guide and Installation Manual __________________________________________ Talon Model Name 20731 __________________________________________ Model No.
  • Page 2: Table Of Contents

    • To reduce the risk of fire, electrical shock, or motor damage, do not 9 • Troubleshooting....15 use a solid-state speed control with this fan. Use only Hunter speed controls.
  • Page 3 Support Brace Hunter’s patented 3-position mounting system provides you maximum installation flexibility and ease. You can install your Hunter fan in one of three ways, depending on ceiling height and your preference: Low Profile, Standard, or Angled mounting. The steps in this manual include Ceiling instructions for all three Installer’s Choice mounting methods.
  • Page 4: Getting Ready

    • Drill holes for and install wood screws. • Identify and connect electrical wires. • Lift 40 pounds. If you need help installing the fan, your Hunter fan dealer can direct you to a licensed installer or electrician. Gathering the Tools You will need the following tools for installing the fan: •...
  • Page 5: Installing The Hanger Bracket

    Tighten the screws into the 9/64” pilot holes; do not use lubricants on the screws. Do not over tighten. Flat Washer Steps 2-2 – 2-4 Ceiling Peak Ceiling Peak Large Large Opening Opening 3” Screw LEFT RIGHT Step 2-3 (Angled Ceiling Only) 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 6: Installing The Blades

    3 • Installing the Blades 3-1. Attach each blade to a blade iron using five blade washers and five blade assembly screws. Step 3-1 Blade Assembly Screws Blade Washers Blade Assembly Screw 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 7: Assembling And Hanging The Fan

    4-6. Align the notch on the ball with the indent in the hanger bracket. (Rotate the fan until you hear the notch pop into place.) Go to 5 • Wiring the Fan. WARNING: Fan may fall if not assembled as directed in these installation instructions. 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 8 WARNING: Fan may fall if not assembled as directed in these installation instructions. Steps 4-9 – 4-10 Low Profile Washer Step 4-8 (Detail) Low Profile Washer Adapter Canopy Trim Ring #8-32 x 3/4” Screw Step 4-11 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 9: Wiring The Fan

    5-7. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 10: Installing The Canopy And Canopy Trim

    6-6. Twist canopy trim ring clockwise to secure the canopy. Should you need to remove the canopy trim ring, follow these steps: 1. Twist canopy trim ring counter clockwise until it releases from canopy. Step 6-3 Step 6-4 Canopy Step 6-5 Screw 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 11: Completing Your Installation With A Bowl Light Fixture

    7 • Completing Your Installation With a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly. WARNING: Use only the light fixture supplied with this fan model. 7-1. To attach the upper switch housing, partially install two housing assembly screws into the switch housing mounting plate.
  • Page 12 190 Watts. Exceeding that limit or the marked limit on this product may result in fire hazard or improper operation. 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 13 7-13. Attach the glass bowl to the light kit by twisting it counterclockwise until it snaps into place. Light Bulbs (B10 Candelabra- Notch Based, 40 Watt Maximum) Breakaway Connector Tabs Glass Bowl Do Not Use Use this Bulb this Bulb 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 14: Fan

    Turn the fan off and let it come to a complete stop. Remove the glass bowl. Slide the reversing switch on the fan to the opposite position. Reinstall the glass bowl. Restart fan. Reversing Switch 45034-01 • 10/23/08 • Hunter Fan Company...
  • Page 15: Troubleshooting

    If you need parts or service assistance, please call 888-830-1326 or visit us at our Web site at http://www.hunterfan.com. Hunter Fan Company 2500 Frisco Avenue Memphis, Tennessee 38114 45034-01 • 10/23/08 • Hunter Fan Company...

This manual is also suitable for:

23351

Table of Contents