❐ Mount the 6107 into the junction box with the two junction box
screws.
❐ Turn the circuit breaker back on.
❐ Preset the controls: Time to minutes, Photo Adjustment fully
clockwise. Cover the lens with masking tape.
❐ With the motion sensor in the "ON" position, turn the remote
switch on and off several times. Go to step 1, 2, or 3, depending
on results.
troubleshooting Wiring connections
* turn power off before rewiring!
If light does not
1.
turn on:
If light turns on in
2.
only one position
of remote switch:
If light turns
on with remote
3.
switch in either
position:
595-4514-16
Exchange*
Control's
Red ⇔ Black
wires.
Exchange*
Control's
Red ⇔ Brown
wires.
Set sensor to "AUTO". Wait for the
unit to warm up (up to 1 min.). If the
remote switch can turn the lights on,
Black ⇔ Brown wires. Remove
the tape. Go to the next page.
-7-
inStallation
Test again. Go
Test again. Go
it's OK. Otherwise:
Exchange* Control's
to 2 or 3.