Heath Zenith Instant Motion Sensor Light Control SL-5211 Owner's Manual

Instant motion sensor light control
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Instant Motion Sensor
Light Control
Model SL-5211
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must be
wired through a switch.
• Some codes require installation by a qualified elec-
trician.
The SL-5211 package includes:
• The Sensor and Lamp Module
• Two mounting screws
Typical Installation
The lamp module is not weather tight. It should only be
used inside of a light fixture.
Existing Light
Fixture
Sensor
Module
Sensor
Cord
© 2007 HeathCo LLC
Features
Parts
Lamp
Module
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5 or 10 min
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
circuitry to calibrate.
Put the ON-TIME switch on the bottom of
the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
MANUAL MODE
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.
Works:
Day
x
1
/
minutes for the
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
595-4238-07
Night
x
x
x

Advertisement

Table of Contents
loading

Summary of Contents for Heath Zenith Instant Motion Sensor Light Control SL-5211

  • Page 1 Instant Motion Sensor Light Control Model SL-5211 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Override, the control must be wired through a switch.
  • Page 2: Installation

    INSTALLATION ❒ Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX to avoid electrical shock. There are two types of decorative fixtures that the Instant Light Control should be used with as shown here. ‘A’...
  • Page 3: Test And Adjustment

    TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 ❒ Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.
  • Page 4: Troubleshooting Guide

    SYMPTOM POSSIBLE CAUSE Light will not come 1. Light switch is turned off. 2. Flood light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in effect (recheck after dark) . 5.
  • Page 5 CONTROL DE LUZ DECORATIVO SENSOR DE MOVIMIENTO Modelo SL-5211 Características • Prende la luz cuando detecta movimiento. • Apaga la luz automáticamente. • La fotocélula mantiene la luz apagada durante el día. Requisitos • El Control de Luz requiere 120 VCA. •...
  • Page 6 INSTALACION ❒ Antes de continuar con la instalación, CORTE LA ENERGIA QUE VA AL CIRCUITO DE LA LUZ DESDE EL CORTACIRCUITOS O DESDE LA CAJA DE FUSIBLES para evitar un sacudón eléctrico. Existen dos tipos de instalaciones fijas decorativas que se deben usar con el Control Ins-tantáneo de Luz, como se demuestra en la figura baja.
  • Page 7: Prueba Y Ajuste

    PRUEBA Y AJUSTE ❒ Prenda el cortacircuitos y el interruptor de luz. NOTA: El detector tiene un período de cerca de 1 de calentamiento antes de detectar movimiento. Cuando lo prenda por primera vez, espere 1 ❒ Gire el control de sensibilidad (SENS) a el medio, y el control de tiempo (ON-TIME) a la posición de prueba (TEST).
  • Page 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. enciende. 2. El faro está flojo o fundido. 3. El fusible está quemado o el cortacircuitos está apagado. 4. La desconexión de luz del día está en efecto. (Compruébelo al anochecer) .

Table of Contents