Service Test 30 – Auger Motor
This test will energize the auger motor.
Pressing the Power Interrupt Button will energize the
motor when the dispenser switch is also actuated.
Service Test 31 – Chute Solenoid
This test will energize the chute solenoid.
Pressing the Power Interrupt Button will energize the
chute solenoid.
Service Test 32 – Water Valve
This test will energize the water valve(s) for the dispenser.
Pressing the Power Interrupt Button will energize the
water valve so long as the dispenser switch is activated.
Service Test 33 – Force Defrost and Exit
This test will initiate a defrost cycle and exit the Service
Test Mode.
Pressing the Power Interrupt Button will initiate the
defrost cycle.
Release the door switch to return to normal operation.