2-1-2.
Indoor Unit
Outdoor Unit
Voltage Rating
Total Capacity
Sensible Capacity
Latent Capacity
Air Circulation (Hi/Me/Lo)
Moisture Removal (High)
Available Voltage Range
Running Amperes
Power Input
Power Factor
EER
COP
SEER
HSPF
Compressor Locked Rotor Amperes
Fuse or Circuit Breaker Capacity
Controls / Temperature Control
Control Unit
Timer
Fan Speeds
Airflow Direction (Indoor)
Air Filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant Control
Operation Sound
Refrigerant Tubing Connections
Max. allowable tubing length at shipment
Refrigerant
Tube Diameter
Wired Remote Controller (Option)
CS-KE18NB4UW & CZ-18BT1U
CU-KE18NKU
ft
3
/min (m
BTU/h/W
BTU/Wh
BTU/Wh
Indoor / Outdoor
Horizontal
Indoor : Hi/Me/Lo
Outdoor : Hi
Narrow tube
inch (mm)
Wide tube
inch (mm)
Cooling
BTU/h
17,500
( 4,000 to 17,500 )
kW
5.15
( 1.2 to 5.15 )
10,600
BTU/h
BTU/h
6,900
3
/h)
341(579) / 294(500) / 253(430)
Pints/h
4.89
V
A
8.3
( 1.2 to 8.3 )
W
1,860
( 250 to 1,860 )
%
97
9.41
W/W
-
16
-
A
A
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi, Me, Lo)
Vertical
Ibs (g)
dB-A
44 / 40 / 36
dB-A
51
ft (m)
9
230V Single-Phase 60Hz
Heating
20,400
( 4,400 to 20,400 )
6.0
( 1.3 to 6.0 )
383(651) / 324(551) / 265(450)
187 to 253
10.5
( 1.3 to 10.5 )
2,340
( 270 to 2,340 )
17.5
15
-
Auto
Washable, Anti-Mold
DC Twin Rotary (Inverter)
R410A / 2.87 (1,300)
Electric Expansion Valve
44 / 40 / 36
Flare Type
25 (7.5)
1/4 (6.35)
1/2 (12.7)
CZ-RD515U
< 230V >
-
-
-
97
-
2.56
-
8.5
52