2-2-2. Outdoor Unit

Outdoor Unit
CU-KE12NK1
Control PCB
Part No.
Controls
Control Circuit Fuse
Compressor
Type
Compressor Model / Nominal Output
Compressor Oil ... Amount
Coil Resistance (Ambient Temp. 68 °F (20 °C))
Safety Device
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Overload Relay
Run Capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool / Heat)
Nominal Output
Coil Resistance
(Ambient Temp. 68 °F (20 °C))
Safety Device
Type
Over- Current Protection
Run Capacitor
Heat Exchanger Coil
Coil
Rows
Fins per inch
Face Area
External Finish
Pints (cc)
Ohm
Model
Operation Temp.
Open : 239 °F (115 °C), Close : 203 °F (95 °C)
Micro F
VAC
inch (mm)
W
Ohm
Micro F
VAC
2
2
ft
(m
)
15
CB-CU-KE12NK1
Microprocessor
125V 25A
DC Rotary (Hermetic)
G4C090LU1ER / 900W
FV50S ... 0.68 (320)
U - V :
0.81
V - W :
0.81
W - U :
0.81
Yes
Yes
Yes
CS-7L115
-
-
115V 20W
Propeller
1 ... D15-3/4 (D400)
DC Motor
SIC-67FV-F460-1... 1
8
750 / 750
50
RED - WHT :
77.5
WHT - BLU :
77.5
BLU - RED :
77.5
Internal Controller
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
18.1
3.95 (0.367)
Acrylic baked-on enamel finish