Step 1
Locating the
Fireplace
MODEL: 6000TRS-CE
Minimum Clearances from the Fireplace to Combustible Materials
Glass
Floor
Front
91.4cm
0
Minimum Clearances from the Flue Pipe to Combustible Materials
For Horizontal Sections
Top
Bottom
7.6cm
2.54 cm
Figure 3. Minimum Clearances
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
1"MIN. (2.54cmm)
NOTE:
*
Dimensions are
shown with the
sides, back
and/or corners
of the unit
touching the wall.
A
B
106.6cm
55.9cm
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
Clearance Requirements
The top and back of the fireplace are defined by
stand-offs.
The minimum clearance to a perpendicular wall
extending past the face of the fireplace is 7.62cm.
The back of the fireplaces may be recessed into
combustible construction (see Figure 3).
RECESSED DEPTH: 54.6cm
Back of
Sides of
Fireplace
Fireplace
1.3cm
1.3cm
For Vertical
Sections
Sides
2.54 cm
2.54 cm
B
A
E
C
D
100.3cm 143.5cm 203.2cm
Top of
Fireplace
8.9cm
At Wall Firestops
Top
Bottom
6.4 cm
1.3 cm
D
20"
(50.8cm)
C
E
Ceiling
79cm
Sides
2.54 cm