Heat & Glo 6000TRS-CE Installer's Manual page 15

Hearth & home technologies gas fireplaces installer guide
Hide thumbs Also See for 6000TRS-CE:
Table of Contents

Advertisement

V
Figure 9.
Flue with One 90° Elbow
FLUE WITH ONE (1) 90
V
MIN. 30.5 cm
MIN. 61.0 cm
MIN. 91.4 cm
MIN. 1.22 m
V + H = MAX 7.3 m
NOTE: For corner installations: A 15.2cm
MINIMUM length of straight pipe must be first
attached to the fireplace before 90
will allow the flue pipe to clear the top standoffs.
o
NOTE: If a 90
elbow is first attached to the unit,
the maximum horizontal run is 3 feet (91.4cm).
Figure 10. Flue with One 90° Elbow
FLUE WITH ONE (1) 90
H
V
MIN. 30.5 cm
MIN. 61.0 cm
MIN. 91.4 cm
MIN. 1.22 m
MAX. 7.3 m
o
ELBOW
H
MAX. 1.22 m
MAX. 2.4 m
MAX. 3.7 m
MAX. 4.9 m
H = MAX. 2.4 m
H
o
elbow. This
o
ELBOW
H
MAX. 61.0 cm
MAX. 1.22 m
MAX. 1.86 m
MAX. 2.48 m
MAX. 2.48 m
V
15