Baud [Xxxxx Abc]; Buff [On, Off] [Xxx] - GE MDS 4710A Technical Manual

Mds 4710/9710 series 400 mhz and 900 mhz remote data transceivers
Table of Contents

Advertisement

Data Interface Port
Baud Rate
RX Data Buffer
24

BAUD [xxxxx abc]

This command sets (or displays) the communication attributes for the
DATA INTERFACE
port. It has no effect on the RJ-11
The first parameter (
xxxxx
bits-per-second (bps) and must be set to one of the following speeds:
1200, 2400, 4800, 9600, or 19200.
The second parameter of the
block indicating how the data is encoded:
= Data bits (7 or 8)
a
= Parity (N for None, O for Odd, E for Even)
b
= Stop bits (1 or 2)
c
The factory default setting is 9600 baud, 8 data bits, no parity, 1 stop bit
(Example:
).
9600 8N1
NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and are
not supported by the transceiver.

BUFF [ON, OFF] [xxx]

This command sets or displays the received data handling mode of the
radio. The command parameter is either
This command affects the timing of how received RF data is sent out
DATA INTERFACE
from the
affected by this command.
If data buffering is
OFF
average latency. Data bytes are thus sent out the
as soon as an incoming RF data frame is disassembled. Average and typ-
ical latency will both be below 10 ms, but idle character gaps might be
introduced into the outgoing data flow.
If data buffering is
ON
will be sent over the air as quickly as possible, but the receiver buffers
(stores) the data until enough bytes have arrived to cover worst-case
gaps in transmission. This mode of operation is required for protocols
such as MODBUS™ that do not allow gaps in their data transmission.
Seamless Mode (
BUFF ON
transmitter's baud rate is greater than or equal to the receiver's baud
rate. Enforcement of this rule is left to the user.
In some rare cases, the default timing parameters for Seamless Mode are
not optimal. In these cases, the user might need to specify an exact delay
time. To set a custom delay time, enter
1 and 255). Entering
BUFF xxx
MDS 4710/9710 Technical Manual
) is baud rate. Baud rate is specified in
command (
BAUD
ON
connector. Outgoing (transmitted) data is not
, the radio operates with the lowest possible
, the radio operates in Seamless Mode. Data bytes
) is intended only for applications where the
BUFF xxx
resets the default delay time.
DIAG
port.
) is a three-character
abc
or
. The default is
OFF
DATA INTERFACE
(
is a value between
xxx
MDS 05-3305A01, Rev. E
.
ON
port

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 4710m

Table of Contents