Lennox Hearth Products MONTECITO MONTE Installation And Operation Instructions Manual
Lennox Hearth Products MONTECITO MONTE Installation And Operation Instructions Manual

Lennox Hearth Products MONTECITO MONTE Installation And Operation Instructions Manual

Epa wood-burning fireplace signature collection
Hide thumbs Also See for MONTECITO MONTE:

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
A French manual is available upon request. Order P/N 850037CF.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 850037CF.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
WARNING
Listed to standards:
ULC-S610 and UL-127
Report No. 307-4084
EPA Cert. No. 537
PIMONTECITO REV. 12 05/2013
INSTALLATION AND

OPERATION INSTRUCTIONS

MONTECITO™
EPA Wood-Burning Fireplace
P/N 850037M REV. M 05/2013
MODEL
MONTE
This installation manual will enable you to obtain a safe, efficient
and dependable installation of your fireplace system. Please read
and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any cir-
cumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct replacement door or firescreen.
• The fireplace is equipped with a blower, electri-
cal connection must be made prior to fireplace
installation
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products MONTECITO MONTE

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS MONTECITO™ EPA Wood-Burning Fireplace P/N 850037M REV. M 05/2013 MODEL MONTE This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or its components under any cir- cumstances.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. the fireplace is free from debris treatments for windows located near the fireplace. Avoid using and any other obstructions that WARNING combustible flowing window...
  • Page 3: Table Of Contents

    CONGRATULATIONS! - AC Chimney Outside Air Kit - Gravity Venting System When you purchased your new fireplace, you joined the ranks of thousands of individuals - Rigid Firescreen whose answer to their home heating needs reflects their concern for aesthetics, efficiency Not tested under EPA certification.
  • Page 4: Starting And Maintaining A Fire

    the left side. The main source of air (primary For instance, a long chimney will necessitate WARNING air) entering the firebox can be diminished by closing the damper more. To obtain the proper combustion, close the damper completely, then moving the air combustion control from left Be careful adding wood fuel to the open it about 1/4”...
  • Page 5: Important Cautions

    Dealing With a Chimney Fire A. Negative pressure in the house - As the fire G. Do not burn driftwood which has been in the burns, air goes up the chimney. This air ocean or salt water. The salt will corrode must be replaced through leakage into the the firebox and chimney.
  • Page 6: Disposing Of Ashes

    DISPOSING OF ASHES NOTE: For better performances, we recom- mend leaving 1/2 inch of ashes in the firebox. Remove ashes only when the fire is out and the ashes are cold (24 to 48 hours after the fire is out). Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases.
  • Page 7: Facade Installation

    Facade Installation WARNING: THE HEARTH EXTEN- Install the Facade per instructions provided in Fireplace SION IS TO BE INSTALLED ONLY Facade Kit (ordered separately - see Page 20). AS ILLUSTRATED. Framing, Facing And Mantel The crack between the fireplace and the hearth extension must be Safety Metal Strip The construction of the framing, facing, and sealed with a non-combustible...
  • Page 8: Framing Dimensions

    Back Wall of Chase/Enclosure OUTSIDE CHASE FRAMING DIMENSIONS Including Finising Materials if any Corner Installation Fireplace Opening Width 19-19/32” 36-1/4” 921 mm 42” 1067 mm * Zero Clearance From Back 30-1/16” 764 mm Spacer to Wall 13-1/2” 343 mm 77” 1956 mm 37-1/2”...
  • Page 9: Nailing Flanges

    Insulate Joists Same As Ceiling INSULATED CHASE CONSTRUCTION Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling Firestop NOTE: It is recommended that the Wall chase walls and floor be insulated CTDT in the same manner, using the Termination same insulation, as the rest of the building, below the attic.
  • Page 10: Fireplace Blower

    HOT AIR DUCTING INSTALLATION Only non-combustible mate- Frame rial should be superposed or The Montecito™ wood burning fireplace is projecting over the front of Grill approved for use with a Gravity kit (hot air the fireplace. ducting system). Gravity Kit The gravity kit is designed for double hot air outlets and includes: (See Figure 14).
  • Page 11: Outside Air Kit

    OUTSIDE AIR KIT It is mandatory to install an outside air connec- Rain Cap tion to the Montecito™ wood burning fireplace. The following components are required and are included with the fireplace: Flashing Collar Flashing • Outside air kit (includes 4 inch flex that goes up to ten (10) feet long) Roof Support •...
  • Page 12: Chimney System

    5. All chimney installations must include at least one support. Re- OUTSIDE CONNECTION ducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands. This can be achieved by having the chimney supported by the supports. The maximum Outside Aluminum Tape chimney length that can be supported by the fireplace is nine (9)
  • Page 13: Chimney Installation Instructions

    CHIMNEY INSTALLATION Attic Radiation Shield INSTRUCTIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 21). Use a plumb-bob to line up the center of the holes.
  • Page 14: Offset Chimney Installation

    After reaching the location requiring the AC * elbow, proceed as follows: Air Cooled Chimney Chimney ASHT+ / HT6103+ / S-2100+ / HT6000+ Collar Chimneys Spacer (built 1. Install the first elbow; turn it in the required into flashing) direction. Fasten it to the chimney with the three (3) 1/2”...
  • Page 15 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 16: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD OFFSET CHIMNEY INSTALLATION (RSM+ and RSMI30) Chimney AC When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. RSMI45 NOTE: 45º...
  • Page 17: Glass Care - Replacement

    Gasket Replacement If possible, you should choose a location where GLASS CARE the chimney will pass through the house without Remove the door from the unit (see Page 6) Glass Replacement cutting floor or roof joists (see fireplace dimen- and lay it on a clean unabrasive surface. To The glass used for the Montecito™...
  • Page 18: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) This support has three possible uses: 18” (460 mm) 1. For ASHT+ / HT6103+ and S-2100+ / HT6000+ , it must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
  • Page 19: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1- Position the fireplace in its location. Temporarily install the ASHT+ WARNING: Before starting the installation, the masonry chimney must elbow on the top of the fireplace and, using a level, mark with an oval be inspected by a qualified chimney sweep.
  • Page 20: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./ Part No. Description Cat./ Part No. Rigid firescreen BUCEBWZN Facades (Required - Order Separately) Central Forced Air Kit Accessories Montecito™ Facade Black, MFBK H4843 Central Forced Air Kit, Central forced air kit including: blower Montecito Facade Hammered Steel, MFMC H4845 (BISZY), flex adaptor (BISAF), 2 clamps, variable speed...
  • Page 21: Replacement Parts

    REPLACEMENT PARTS LIST SPECIFICATIONS Montecito™ Replacement Parts Cat. No. Model Description Part/Cat. No. H4841 Montecito Blower (heat activated on/off pre-wired), UZY5 UZY5 Blower motor speed control (wall mount), VRUW VRUW Product Reference Information Weight 300 lbs Snap Disc, Blower Height 36”...
  • Page 22: Chimney Components Lists

    SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 2125 Monterey, Laval, Quebec 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada) www.securitychimneys.com Fireplace Model MONTE - Approved Venting Components manufactured...
  • Page 23 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 Tubinox™ LL Chimney Lining System 2125 Monterey, Laval, Quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6”...
  • Page 24: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.

Table of Contents