SAS-827T Backplane User's Guide
2-3 Front Jumper Locations and Pin Definitions
JP57
FAN4
4
BAR CODE
1
+
F16
C269
7
OH
+
A
R11
#D2
D11
U3
U4
C130
JP49
10
C
6
1
R226
R202
5
C173
JF4
JP49:
JF1-D
7
MB-D
JP47
(FAN)
1
4
+
#D1
1
JP65
JF6
C199
7
JF1-CD
JF3
1
C156
D72
2
JF1-C
#D0
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
R R R R R R R R R R
R
SILKSCREEN
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UPER
UNLESS OTHERWISE
PRIMARY-SIDE
SPECIFIED DIMENSIONS
ARE IN INCHES
PROJECT NAME:
SAS827T
TOLERANCES
DESIGNED BY SUPERMICRO U.S.A.
DECIMAL
ANGLE
www.supermicro.com
DATE:
01/19/2009
REV:
1.01
X
.1
30
XX
.03
MACH FINISH
SAN JOSE,CA 95131
DESINGER:
Shen
XXX
.010
TEL:408-503-8000 FAX:408-503-8008

Explanation of Jumpers

To modify the operation of the backplane,
jumpers can be used to choose between
optional settings. Jumpers create shorts
between two pins to change the function
of the connector. Pin 1 is identified with
a square solder pad on the printed circuit
board. Note: On two pin jumpers, "Closed"
means the jumper is on and "Open" means
the jumper is off the pins.
Jumper
Open: Buzzer disabled
JP18
1-2: Buzzer enabled (Default)
2-3: Test setting
Overheat Settings
Open: 45º Celsius
JP30
1-2: 50º Celcius (Default)
2-3: 55º Celcius
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The backplane buzzer alarm is triggered by the following condition:
Backplane temperature over 45º, 50º or 55º Celsius, depending upon the overheat
setting selected. See the table above for details.
JP30
JP30
4
1
3
1
JP56
HB
FAN3
D1
SAS827T
A
C
7
REV 1.01
F15
TP3
34
33
L2
U8
C201
11
23
#C2
U6
12
R199
JP30:
+
OPEN:45
C
1-2:50
C DEFAULT
U10
2-3:55
C
C198
7
U11
R222
MB-C
(FAN)
1
4
MB-D
#C1
+
C197
(PWR)
4
1
JP60
JP46
7
C121
F7
F8
DESIGNED IN USA
#C0
Figure 2-8: Front Jumpers
Jumper Settings
Jumper Settings
To P/S
FAN2
JP48
JF2
F14
4
1
JP55
19
C209
4
U7
1
7
D65
D68
JP69
F18
C115
+
#B2
C3
6
1
1
+
R144
2
JP26
R145
R196
U2
C43
JF1-B
C119
U9
D64
7
D59
19
MB-B
(FAN)
1
4
#B1
C44
+
1
JP13
JP59
4
MB-C
7
(PWR)
D58
D63
2
1
JF1
JF1-A
#B0
*Buzzer reset
Backplane overheat settings
2-6
1
C45
F13
C266
4
+
FAN1
JP54
D57
7
D62
C15
C58
10
C85
C75
#A2
BUZZER RESET
+
C19
5
U1
R113
JP18
R110
R104
D61
D56
7
JP58
JP10
C84
1
4
+
#A1
4
MB-B
1
(PWR)
MB-A
MB-A
(PWR)
(FAN)
7
D60
D55
C23
C21
#A0
3
2
Connector
Pins
Jumper
3
2
Setting
Notes
BZ1
JP18
R297
1
3
JP18
OPEN:BUZZER DISABLE
1-2:BUZZER ENABLE
2-3:TEST
F3
C33
4
JF1-AB
JF5
1
1

Advertisement