Flash/St Robe - Hasselblad CF22 CF39 User Manual

Digital back for medium format cameras
Table of Contents

Advertisement

9
Flash / Strobe
A CF digital back can be used together with
most studio or portable units.
When attached to a 503CW (or 503CWD), the
TTL function is also available.
Most flash units are suitable for use with a CF digital back. However, for safety
reasons, care should be taken when using studio flash units (strobe) and teth-
ered to a stationary computer.
Portable units
Attach the flash sync cable to the lens (or camera body in the case of a Hasselblad 200
series model) and make the appropriate settings according to the unit.
This also applies when using studio units when:
a) tethered to a computer not connected to a regular electricity supply system.
or
b) tethered to an Imagebank or laptop computer running on batteries.
With studio type flash units (strobe) and tethered to a computer
If the CWD is tethered to a computer that is connected to a regular electricity supply
system as well as a studio flash/strobe unit that is also connected to a regular electricity
supply system/generator system, then make the following connections instead:
a) Connect the flash sync input cable from the sync contact (PC connector) on the lens
to the flash sync IN terminal on the back.
b) Connect the flash sync output cable from the flash sync OUT terminal on the back
to a regular flash sync cable that is connected to the unit.
TTL function – 503CW /503CWD only
A TTL function is only available with the 503CW/D. The reflective characteristics of the
digital sensor are different to film surface characteristics for which the TTL function
was originally designed. However, by changing (in effect, 'tricking') the setting, TTL
exposures can be made. Proceed as follows:
Move the ISO selector on the 503CW/D so that is becomes approximately 1⅔ f/stop higher
than the ISO setting on a CF digital back. Therefore, for example, when the back is set at
50ISO, the 'film speed setting' on the camera should read 160ISO, and so on. Testing for
the most suitable compensation that suits you is recommended.
See appropriate manuals for connection details regarding the various units and
adapters.


Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf22msCf39ms

Table of Contents

Save PDF