Troubleshooting schedule

Keypad
Possible fault codes on the chain saw keypad.
Keypad
Warning indicator flashing.
Green activate LED flashing.
Warning indicator lit.
Battery
Troubleshooting the battery and/or the battery charger during charging.
LED display
Warning indicator flashing.
Warning indicator lit.
Battery charger
LED display
Warning indicator flashing.
Warning indicator lit.
38 – English
MAINTENANCE
Possible faults
Chain brake engaged.
Temperature deviation
Overload.
The power trigger and the
activate button are pressed at
the same time.
Low battery voltage.
Service
Possible faults
The battery is discharged.
Temperature deviation
Over voltage
Cell difference too much (1V)
Possible faults
Temperature deviation
Possible action
Pull back the front hand guard to
release the chain brake.
Allow the machine to cool down.
The cutting attachment is jammed.
Release the cutting attachment.
Release the power trigger and the
machine is active.
Charge the battery.
Contact your service agent.
Possible action
Charge the battery
Use the battery in surroundings
where temperatures are between
-10 °C and 40 °C.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the
battery charger.
Contact your service agent.
Possible action
Use the battery charger only when
the surrounding temperature is
between 5 °C and 40 °C.
Contact your service agent.