Conversion kit

Advertisement

Table Of Contents

General Information ................................................................. 2
Parts list .................................................................................... 2
A.Conversion
1. Before you begin ........................................................ 3
2. Ember Burner ............................................................. 3
3. Main Gas Regulator ................................................... 3
4. Pilot Assembly ............................................................ 3
5. Main Burner................................................................ 4
B. Check the Gas Pressure ...................................................... 4
C. Adjusting the Pilot Burner................................................... 4
Operation ................................................................................... 5
Page 
M40 Series Mobile Home Conversion Kit

General Information

This gas conversion kit contains the necessary components for field
conversion of an approved Montigo fireplace from Natural Gas (NG)
to Liquid Propane (LP), or from LP to NG. See this kit for use with the
following manufactured (mobile) home models:
 M40DV-PFC (MH)  M40DV-CR/CL (MH)
 M40DV-ST (MH)
A manufactured (mobile) home OEM installation in the United States
must conform with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a standard is not
applicable, the Standard for Manufactured Home Installations, ANSI
/ NCSBCS A225.1. In Canada, the installation must conform to the
Standard for Gas Equipped Recreational Vehicles and Mobile Hous-
ing, CSA Z240.4.
The installation of this unit must also conform with local codes or, in
the absence of local codes, with the American National Fuel Gas
Code, ANSI Z223.1, or the Canadian Installation Code, CAN / CGA
WARNING!
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation
of the converted appliance is checked as specified in the
manufacturer's instructions supplied with this kit.

Parts List

Quantity
Description
2
Sleeves (main burner)
2
Pilot burner orifice
1
Ember burner orifice
1
Main burner orifice
1
Label for rating plate indicating conversion
1
Label for gas control valve indicating conversion
P/N XG0640