Advertisement

Quick Links

2
6
3
4
>
1
=
ARABELLA
gEBRAUchsAnWEisUng
BRUgsAnVisning
MAnUEL D'UTiLisATiOn
OPERATing MAnUAL
isTRUziOni D'UsO
gEBRUiKsAAnWiJzing
BRUKsAnVisning
2
18
34
50
66
82
98

Advertisement

Table of Contents
loading

Summary of Contents for Zibro ARBELLA

  • Page 1 ARABELLA gEBRAUchsAnWEisUng BRUgsAnVisning MAnUEL D’UTiLisATiOn OPERATing MAnUAL isTRUziOni D’UsO > gEBRUiKsAAnWiJzing BRUKsAnVisning...
  • Page 2 iMPORTAnT cOMPOnEnTs exhaust flue/ chimney (not included in deli- VeRy) exhaust flue dampeR (not included in deli- VeRy) glass cleaning aiR inlet inspection Win- fiRe heaRth dooR gasket handle ash gRid shakeR pRimaRy aiR inlet contRol ash pan (Behind dooR) ash pit dooR adJustaBle feet Room aiR ReciRcu-...
  • Page 3 In order to ensure the maximum life span and safe use of your Zibro heating pro- duct. Please carefully read this manual first and store it for future reference.
  • Page 4: Safety Instructions

    Therefore: • This heater must be installed by a by Zibro authorized heating and installa- tion engineer. The warranty can only be effective when it is installed by a by Zibro agreed professional. The instructions for use given in this manual may vary from local and/or regional legislation.
  • Page 5 • The surface of the stove can become very hot when in use. NEVER leave child- ren unattended with the stove. Children should be supervised to ensure they do not play with the stove. • This stove is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 6 • The connection voltage corresponds to that on the type plate. • The socket and power supply are suitable for the device. • The plug on the cable fits the socket. • Have the electrical installation checked by a recognised expert if you are not sure that everything is in order.
  • Page 7: First Start-Up

    cal legislation and/or insurance company instructions: make sure that at least once per year at the beginning of the heating season your entire stove system -including chimney- is checked and maintained by an authorized specialist. When intensively using the stove the chimney must be cleaned more frequently. c.
  • Page 8 After another 10 minutes close the charging door completely. Check the fi re. Now close the primary air inlet valve to minimal whilst still ensuring good burning fi re (see chapter d.1.1.). DURing nORMAL OPERATiOn: • The primary air inlet valve must be kept to a minimum –whilst still ensu- ring a good burning fi re-, this will ensure that the burning process is as clean as possible and the effi ciency is as high as possible.
  • Page 9 the stove is designed for normal operation with closed charging door. the safe operation and optimal efficiency can only be reached with a closed charging door. keeping the charging door closed will also prevent burning or hot particles from leaving the stove. D.3 REqUiREMEnTs TO ThE FUEL •...
  • Page 10: Maintenance

    E. MAinTEnAncE The heat, ash and residue produced by the combustion of the fire wood makes regular cleaning and maintenance by both the end user as well as an authorized technician necessary. Periodically carefully cleaning the stove is important for safe- ty, efficient operation and -in the same time- increasing the life time of the stove.
  • Page 11 E.2 MAinTEnAncE TO BE DOnE BY AUThORizED TEchniciAn Task Frequency professional inspection and maintenan- twice per season, fi rst time at begin- ce of stove (& fl ue system) ning of season Cleaning/sweeping the chimney/fl ue twice per season, fi rst time at begin- system ning of season replacing parts not mentioned in this...
  • Page 12 Have it replaced by a by Zibro authorized technician if needed. Only use original Zibro spare parts.
  • Page 13: Troubleshooting

    Only use original Zibro spare parts. Using non original Zibro spare parts will lead to nullification of the warranty. g. TROUBLE shOOTing...
  • Page 14: Warranty Provisions

    8. Stove is installed by a by Zibro agreed installer and the commissioning protocol can be presented. In order to avoid unnecessary costs, we recommend that you always carefully read this manual first.
  • Page 15: Technical Data

    (***) to be determined by professional authorized installer For your convenience you can download the latest version of the user-, installation- and/or service manual on www.zibro.com/download. Waste electrical products should not be disposed with household waste. please re- cycle where facilities exist. Check with your local authority or retailer for recycling...
  • Page 16: Declaration Of Conformity

    That the following products comply with the appropriate basic safety and health requirements of the EC Directives based on its design and type: Product Description: Roomheaters fired by Solid fuel Brand of Product: Zibro arabella Reference of Product: Applicable EC Directives: ec construction products directive...
  • Page 18 +32 3 326 39 39 tel: +39 571 628 500 fax: +32 3 326 26 39 fax: +39 571 628 504 email: pvgbelgium@zibro.com email: pvgitaly@zibro.it q SCHWEIZ u NORGE pVg schweiz ag appliance a/s salinenstrasse 63 gefionsvej 7 4133 pRatteln dk-3400 hilleRød...

Table of Contents