Features (Rear Panel) Power Module Feature Description Detachable Power Distribution Unit Feature Description Battery Module Feature Description Connection (continued) Hardwiring Cautions...
Page 7
Connection (continued) Connecting Modules to Each Other and to Utility Power and Equipment Attach the PDU to the Power Module and Battery Module. Hardwire the PDU to a Utility Power Source. Connect the battery module to the power module. Contacts on Power/Battery Module Contacts on Detachable PDU WARNING! High Voltage! WARNING! High voltage!
Connection (continued) Plug Your Equipment into the PDU’s Outlets Turn UPS OFF (Optional) UPS Cold Start (Optional) Optional Connection USB and RS-232 Serial Communication Connection...
Manual Bypass Operation (for power module maintenance or replacement) (continued) High Voltage Warnings Contacts on Power/Battery Module Contacts on Detachable PDU WARNING! High Voltage! WARNING! High voltage! Risk of electrical shock! Risk of electrical shock! Due to the presence of high voltage internal batteries, If AC is present and Bypass Switch is set to “Bypass”, even without AC present, these contacts are live!
Operation (continued) Normal Operation LOAD LEVEL BATTERY CAPACITY 00.00KW / 000% 000V / 000% LOAD LEVEL LOAD LEVEL 00.00KVA / 000% 00.00KW / 000% INPUT VOLTAGE LOAD LEVEL 000V / 00.0Hz 00.00KVA / 000% BYPASS VOLTAGE BYPASS VOLTAGE 000V / 00.0Hz 000V / 00.0Hz OUTPUT VOLTAGE OUTPUT VOLTAGE...
Page 15
Operation (continued) Changing the Password SETUP MENU DOWN Down FOLLOW BASIS SETTING CHANGE PASSWORD? SEQUENCE DOWN DOWN PAGE14 SAVING: NO DOWN Down SAVING: YES DOWN Scroll up back to SETUP MENU Selecting Screen Language SETUP MENU DOWN Down BASIS SETTING CHANGE PASSWORD? DOWN DOWN...
Page 16
Operation (continued) Start Settings START SETTING BATTERY START *ENABLE* DOWN DOWN DOWN To ENTER DISABLE DOWN AUTO RESTART *ENABLE* DOWN DOWN DISABLE DOWN Charger Settings CHARGER SETTING CHARGER CURRENT CURRENT = 1.5A DOWN DOWN DOWN To ENTER CURRENT = 2.0A DOWN CURRENT = 3.0A DOWN...
Operation (continued) Battery Settings BATTERY SETTING BATTERY LOW ALARM DOWN DOWN To ENTER DEEP DISCH TEST *NO TEST* DOWN DOWN 30 DAYS DOWN 60 DAYS DOWN 90 DAYS DOWN QUICK TEST DOWN...
Page 18
Operation (continued) Output Settings Note: Any Output Setting changes require a UPS power cycle. OUTPUT SETTING OUTPUT VOLTAGE *230V* DOWN DOWN DOWN To ENTER 220V DOWN 208V DOWN 200V DOWN 240V DOWN OUTPUT SETTING OUTPUT VOLTAGE DOWN DOWN To ENTER FREQ.
Page 19
Operation (continued) Output Settings OUTPUT SETTING OUTPUT VOLTAGE DOWN DOWN To ENTER FREQ. CONVERTER DOWN ECO MODE *DISABLE* DOWN DOWN ENABLE DOWN OUTPUT SETTING OUTPUT VOLTAGE DOWN DOWN To ENTER FREQ. CONVERTER DOWN ECO MODE DOWN INDUSTRIAL *ENABLE* DOWN DOWN DISABLE DOWN REDUNDANCY...
Page 20
Operation (continued) UPS Alarm Log UPS ALARM LOG READ FROM MEMORY 1 65535 HH:MM:SS DOWN DOWN NO HISTORY To ENTER 2 65535 HH:MM:SS NO HISTORY 3 65535 HH:MM:SS NO HISTORY 4 65535 HH:MM:SS NO HISTORY 5 65535 HH:MM:SS NO HISTORY Fail Event List options.
Page 21
Operation (continued) Self Diagnosis Information DIAGNOSTIC MODE FREQ OUT = 50Hz DIAGNOSTIC MODE INPUT 000V / 00Hz DIAGNOSTIC MODE RECTIFIER OK DIAGNOSTIC MODE CHARGER OK DIAGNOSTIC MODE BATTERY OK DIAGNOSTIC MODE DC BUS OK DIAGNOSTIC MODE INVERTER TEST DIAGNOSTIC MODE INVERTER OK LOAD LEVEL 00.00KW / 000%...
Page 22
Operation (continued) Display Information-Online Mode LOAD LEVEL 00.00KW / 000% LOAD LEVEL 00.00KVA / 000% INPUT VOLTAGE 000V / 00.0Hz BYPASS VOLTAGE 000V / 00.0Hz OUTPUT VOLTAGE 000V / 00.0Hz BATTERY CAPACITY 000V / 000% REMAINING TIME 0000 MINUTES ON-LINE 10KVA V00 CV01 REMAINING TIME 0000 MINUTES...
Page 24
Operation (continued) On Battery Alarm Overload Messages OVERLOAD! LOAD = XXX% X.XXKW Overload Condition Countdown Duration Bypass Messages BYPASS VOLTAGE LCD DISPLAY CONDITIONS MESSAGES >15% Higher BYPS OUT OF VOLT Than Nominal XXXV / XX.X HZ >20% Lower BYPS OUT OF VOLT Than Nominal XXXV / XX.X HZ...
Page 25
Operation (continued) Shutdown Messages SHUTDOWN LCD DISPLAY CONDITIONS MESSAGES Extended SHUT DOWN Overload OVERLOAD XXX% Output Short SHUT DOWN Circuit O/P SHORT CIRCUIT Remote Shutdown SHUT DOWN Command (Via DB9) REMOTE COMMAND Remote Shutdown SHUT DOWN Command (Via EPO) EMERGENCY STOP! SHUT DOWN Internal + DC BUS HIGH...
Warranty and Warranty Registration 2-Year Limited Warranty WARRANTY REGISTRATION FCC Part 68 Notice (United States Only) Regulatory Compliance Identification Numbers WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union) 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support...
Manual del propietario ™ SmartOnline monofásico de 8 kVA-10 kVA Sistemas de alimentación ininterrumpida (UPS) inteligentes realmente en línea (montaje en bastidor/torre) Advertencias de seguridad importantes Montaje Características Conexión Conexión opcional Procedimiento de derivación manual Especificaciones Funcionamiento Almacenamiento y servicio Garantía...
Advertencias de seguridad importantes Advertencias sobre la ubicación del UPS Advertencias sobre la conexión del UPS Advertencias sobre la conexión del equipo Advertencias de mantenimiento Advertencias sobre la batería...
Montaje (torre) Características Controles del panel frontal del módulo de energía...
Page 31
Características (panel trasero). Vea una descripción de los elementos en la página 32 Módulo de energía de 8 kVA/10kVA Unidad desmontable de distribución de energía Módulo de batería...
Características (panel trasero) Descripción de los elementos del módulo de energía Descripción de los elementos de la unidad desmontable de distribución de energía Descripción de los elementos del módulo de batería Conexión Precauciones con el cableado físico Valores nominales de entrada y salida...
Page 33
Conexión Conexión de módulos entre sí, a la energía de la red y al equipo Conecte la PDU al módulo de energía y al módulo de batería. Conecte físicamente la PDU a una fuente de energía de la red. Conecte el módulo de batería al módulo de energía. Contactos del módulo de Contactos de la PDU desmontable energía/batería...
Conexión Conecte el equipo a las tomas de la PDU. Apague el UPS (opcional) Arranque en frío del UPS (opcional) Conexión opcional Conexión de comunicación en serie USB y RS-232...
Conexión opcional Conexión de puerto EPO ASIGNACIÓN DE CLAVIJAS EPO Ventila- LEDs Salidas Serial SNMP Pantalla LCD dores “Parada de Emer- Apagados Apagadas Apagados Apagado Apagado Apagado gencia” Ventila- LEDs Salidas Serial SNMP Pantalla LCD dores “Parada de Emer- Apagados Apagadas Apagados Apagado...
Page 36
Procedimiento de derivación manual (para el mantenimiento o sustitución del módulo de energía) Desmontaje del módulo de energía/batería del UPS Paso 1, 3, 4 ¡ADVERTENCIA! ¡Alto voltaje! ¡Peligro de descarga eléctrica! VER MÁS ABAJO. Paso 2 ¡Ver avisos de advertencia más abajo! ¡ADVERTEN- CIA!
Procedimiento de derivación manual (para el mantenimiento o sustitución del módulo de energía) Advertencias sobre el alto voltaje Contactos del módulo de energía/batería Contactos de la PDU desmontable ¡ADVERTENCIA! ¡Alto voltaje! ¡ADVERTENCIA! ¡Alto voltaje! ¡Peligro de descarga eléctrica! ¡Peligro de descarga eléctrica! ¡Debido a la presencia de baterías internas de alto voltaje, ¡Estos contactos tienen corriente si hay corriente alterna...
Funcionamiento Información de los LED Parpadeando BYPASS BYPASS AC/DC DC/AC AC/DC AC/DC BYPASS BATTERY AC/DC DC/AC BATTERY BYPASS BATTERY AC/DC DC/AC AC/DC...
Page 39
Funcionamiento Autocomprobación de arranque ARRANQUE CON ARRANQUE ENTRADA DE CA EN FRÍO* MODO DIAGNÓSTICO MODO DIAGNÓSTICO FRECUENCIA DE SALIDA FRECUENCIA DE SALIDA = 50Hz = 50Hz MODO DIAGNÓSTICO MODO DIAGNÓSTICO ENTRADA 000V / 00Hz ENTRADA 000V / 00Hz MODO DIAGNÓSTICO MODO DIAGNÓSTICO RECTIFICADOR BIEN RECTIFICADOR BIEN...
Page 40
Funcionamiento Funcionamiento normal NIVEL DE CARGA CAPACIDAD DE BATERÍA 00.00KW / 000% 000V / 000% NIVEL DE CARGA NIVEL DE CARGA 00.00KVA / 000% 00.00KW / 000% VOLTAJE DE ENTRADA NIVEL DE CARGA 000V / 00.0Hz 00.00KVA / 000% VOLTAJE DE DERIVACIÓN VOLTAJE DE DERIVACIÓN 000V / 00.0Hz 000V / 00.0Hz...
Page 41
Funcionamiento Cambio de contraseña MENÚ DE CONFIGURACIÓN ENTRAR ABAJO ARRIBA Abajo SIGA LA CONFIGURACIÓN BÁSICA ¿CAMBIAR CONTRASEÑA? SECUENCIA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA DE LA PÁGINA 40 GUARDAR: NO ENTRAR ABAJO ARRIBA Abajo GUARDAR: SÍ ENTRAR ABAJO ARRIBA Desplácese hacia arriba para volver al MENÚ...
Page 42
Funcionamiento Configuración de arranque hasta llegar a la pantalla CONFIGURACIÓN DE ARRANQUE ARRANQUE CON BATERÍA HABILITAR ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA Para ENTRAR DESHABILITAR ENTRAR ABAJO ARRIBA REINICIO AUTOMÁTICO HABILITAR ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA DESHABILITAR ENTRAR ABAJO...
Page 43
Funcionamiento Configuración de la batería CONFIGURACIÓN DE LA BATERÍA ALARMA DE BATERÍA BAJA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA Para ENTRAR PRUEBA DE DESCARGA PROFUNDA SIN PRUEBA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA 30 DÍAS ENTRAR ABAJO ARRIBA 60 DÍAS ENTRAR ABAJO ARRIBA...
Page 44
Funcionamiento Configuración de la salida Nota: todos los cambios de configuración de la salida requieren un ciclo de trabajo del UPS. CONFIGURACIÓN DE LA SALIDA VOLTAJE DE SALIDA *230V* ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA Para ENTRAR 220V ENTRAR ABAJO...
Page 45
Funcionamiento Configuración de la salida CONFIGURACIÓN DE LA SALIDA VOLTAJE DE SALIDA ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA Para ENTRAR CONVERSOR DE FRECUENCIA ENTRAR ABAJO ARRIBA MODO ECO DESHABILITAR ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA HABILITAR ENTRAR ABAJO ARRIBA CONFIGURACIÓN DE LA SALIDA VOLTAJE DE SALIDA ENTRAR ABAJO...
Page 46
Funcionamiento Registro de la alarma del UPS REGISTRO DE LA ALARMA DEL UPS LECTURA DE MEMORIA 1 65535 HH:MM:SS ENTRAR ABAJO ARRIBA ENTRAR ABAJO ARRIBA SIN HISTORIAL Para ENTRAR 2 65535 HH:MM:SS SIN HISTORIAL 3 65535 HH:MM:SS SIN HISTORIAL 4 65535 HH:MM:SS SIN HISTORIAL 5 65535 HH:MM:SS SIN HISTORIAL...
Page 47
Funcionamiento Información de autodiagnóstico MODO DIAGNÓSTICO FRECUENCIA DE SALIDA = 50Hz MODO DIAGNÓSTICO ENTRADA 000V / 00Hz MODO DIAGNÓSTICO RECTIFICADOR BIEN MODO DIAGNÓSTICO CARGADOR BIEN MODO DIAGNÓSTICO BATERÍA BIEN MODO DIAGNÓSTICO BUS DE CC BIEN MODO DIAGNÓSTICO PRUEBA DE INVERSOR MODO DIAGNÓSTICO INVERSOR BIEN NIVEL DE CARGA...
Page 48
Funcionamiento Información en pantalla: modo en línea NIVEL DE CARGA 00.00KW / 000% NIVEL DE CARGA 00.00KVA / 000% VOLTAJE DE ENTRADA 000V / 00.0Hz VOLTAJE DE DERIVACIÓN 000V / 00.0Hz VOLTAJE DE SALIDA 000V / 00.0Hz CAPACIDAD DE BATERÍA 000V / 000% TIEMPO RESTANTE 00000 MINUTOS...
Page 49
Funcionamiento Información en pantalla: modo derivación NIVEL DE CARGA 00.00KW / 000% NIVEL DE CARGA 00.00KVA / 000% VOLTAJE DE ENTRADA 000V / 00.0Hz VOLTAJE DE DERIVACIÓN 000V / 00.0Hz VOLTAJE DE SALIDA 000V / 00.0Hz CAPACIDAD DE BATERÍA 000V / 000% TIEMPO RESTANTE 00000 MINUTOS EN LÍNEA 10KVA...
Page 50
Funcionamiento Alarma del modo en batería Mensajes de sobrecarga ¡SOBRECARGA! CARGA = XXX% X.XXKW Condición de sobrecarga Duración de la cuenta atrás Mensajes de derivación CONDICIONES DE VOLTAJE DE MENSAJES EN DERIVACIÓN PANTALLA LCD >15% superior DERIVACIÓN FUERA DE VOLTAJE al normal XXXV / XX.X HZ >20% inferior...
Page 51
Funcionamiento Mensajes de apagado CONDICIONES MENSAJES EN DE APAGADO PANTALLA LCD Sobrecarga APAGADO prolongada SOBRECARGA XXX% Cortocircuito APAGADO de salida CORTOCIRCUITO DE SALIDA Comando de apagado APAGADO remoto (vía DB9) COMANDO REMOTO Comando de apagado APAGADO remoto (vía EPO) ¡PARADA DE EMERGENCIA! APAGADO Errores BUS DE DC + ALTO...
Garantía Garantía limitada de 2 años Cumplimiento de las normas de los números de identificación Información de sobre Cumplimiento de la WEEE para Clientes de Tripp Lite y Recicladores (Unión Europea) 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support...
Manuel de l’utilisateur ™ SmartOnline monophasé 8kVA—10kVA Systèmes UPS intelligents à double conversion (montage en rack/tour) Avertissements de sécurité importants Montage Caractéristiques Raccordement Raccordement facultatif Dérivation manuelle Spécifications Utilisation Stockage et entretien Garantie English Español 1111 W. 35th Street, Chicago, IL 60609 USA...
Avertissements de sécurité importants Avertissements concernant l’emplacement de l’UPS Avertissements concernant le raccordement de l’UPS Avertissements concernant le raccordement de l’équipement Avertissements concernant la maintenance Avertissements concernant la batterie...
Caractéristiques (Panneau arrière) Description des caractéristiques du module d’alimentation Description des caractéristiques du distributeur d’alimentation amovible Description des caractéristiques du Module de batterie Raccordement Précautions concernant le câblage Tension nominale d’entrée et de sortie...
Page 59
Raccordement Raccordement entre les modules, au courant de service et à l’équipement Fixez le PDU au module d’alimentation et au module de batterie. Raccordez le PDU à la source d’alimentation du courant de service à l’aide d’un câble. Raccordez le module de batterie au module d’alimentation. Contacts sur le module de batterie/ Contacts sur le PDU amovible d’alimentation...
Raccordement Branchez votre équipement dans les boîtes de sortie du PDU Mettez l’UPS sur OFF (facultatif) sera noir. va devenir noir. Départ à froid de l’UPS (facultatif) Raccordement facultatif Raccordement de communication en série USB et RS-232...
Raccordement facultatif Raccordement du port EPO Remarque : AFFECTATION DE BROCHE EPO 1. Si un câble autre que celui fourni est utilisé, le câble ne devrait pas excéder 106 mètres (350 pieds) ou avoir une résistance supérieure à 10 ohms. 2.
Page 62
Dérivation manuelle (pour l’entretien ou le remplacement du module d’alimentation) Retrait du module d’alimentation/de batterie de l’UPS Étape 1, 3, 4 ATTENTION ! Haute tension ! Risque de choc électrique ! VOIR CI-DESSOUS. Étape 2 Lisez les mises en garde ci-dessous ! ATTENTION ! Haute...
Dérivation manuelle (pour l’entretien ou le remplacement du module d’alimentation) Avertissement concernant la haute tension Contacts sur le PDU amovible Contacts sur le Module d’alimentation/de batterie ATTENTION ! Haute tension ! ATTENTION ! Haute tension ! Risque de choc électrique ! Risque de choc électrique ! En présence de CA et si le commutateur de dérivation En raison de la présence de batteries internes à...
Utilisation Informations sur l’affichage des DEL Clignotant BYPASS BYPASS AC/DC DC/AC AC/DC AC/DC BYPASS BATTERY AC/DC DC/AC BATTERY BYPASS BATTERY AC/DC DC/AC AC/DC...
Page 65
Utilisation Auto-vérification de démarrage DÉMARRAGE EN DÉMARRAGE COURANT CA À FROID* MODE DIAGNOSTIC MODE DIAGNOSTIC FRÉQUENCE DE SORTIE = 50Hz FRÉQUENCE DE SORTIE = 50Hz MODE DIAGNOSTIC MODE DIAGNOSTIC ENTRÉE 000V / 00Hz ENTRÉE 000V / 00Hz MODE DIAGNOSTIC MODE DIAGNOSTIC REDRESSEUR OK REDRESSEUR OK MODE DIAGNOSTIC...
Page 66
Utilisation Fonctionnement normal NIVEAU DE CHARGE CAPACITÉ DE LA BATTERIE 00.00KW / 000% 000V / 000% NIVEAU DE CHARGE NIVEAU DE CHARGE 00.00KVA / 000% 00.00KW / 000% TENSION D’ENTRÉE NIVEAU DE CHARGE 000V / 00.0Hz 00.00KVA / 000% TENSION DE DÉRIVATION TENSION DE DÉRIVATION 000V / 00.0Hz 000V / 00.0Hz...
Page 67
Utilisation Modifier le mot de passe MENU CONFIGURATION ENTRER HAUT VOIR PARAMÈTRES DE BASE MODIFIER MOT DE PASSE ? SÉQUENCE ENTRER HAUT ENTRER HAUT PAGE 66 ENREGISTRER : NON ENTRER HAUT ENREGISTRER : OUI ENTRER HAUT Revenez MENU CONFIGURATION Sélectionner la langue MENU CONFIGURATION ENTRER HAUT...
Page 68
Utilisation Paramètres de démarrage PARAMÈTRES DE DÉMARRAGE DÉMARRAGE EN MODE BATTERIE ACTIVER ENTRER HAUT ENTRER HAUT ENTRER HAUT Pour ENTRER DÉSACTIVER ENTRER HAUT REDÉMARRAGE AUTOMATIQUE ACTIVER ENTRER HAUT ENTRER HAUT DÉSACTIVER ENTRER HAUT Paramètres du chargeur PARAMÈTRES DU CHARGEUR COURANT DU CHARGEUR COURANT = 1.5A ENTRER HAUT...
Page 69
Utilisation Paramètres de la batterie PARAMÈTRES DE LA BATTERIE ALERTE DE BATTERIE FAIBLE ENTRER HAUT ENTRER HAUT Pour ENTRER TEST DE DÉCHARGE COMPLÈTE AUCUN TEST ENTRER HAUT ENTRER HAUT 30 JOURS ENTRER HAUT 60 JOURS ENTRER HAUT 90 JOURS ENTRER HAUT TEST RAPIDE ENTRER...
Page 70
Utilisation Paramètres de la puissance de sortie Remarque : pour modifier les paramètres de la puissance de sortie, vous aurez besoin du cycle électrique de l’UPS. PARAMÈTRES DE LA PUISSANCE DE SORTIE TENSION DE SORTIE *230V* ENTRER HAUT ENTRER HAUT ENTRER HAUT Pour ENTRER...
Page 71
Utilisation Paramètres de la puissance de sortie PARAMÈTRES DE LA PUISSANCE DE SORTIE TENSION DE SORTIE ENTRER HAUT ENTRER HAUT Pour ENTRER CONVERTISSEUR DE FRÉQUENCE ENTRER HAUT MODE ÉCONOMIE D’ÉNERGIE DÉSACTIVER ENTRER HAUT ENTRER HAUT ACTIVER ENTRER HAUT PARAMÈTRES DE LA PUISSANCE DE SORTIE TENSION DE SORTIE ENTRER HAUT...
Page 72
Utilisation Historique des alertes de l’UPS HISTORIQUE DES ALERTES DE L’UPS LIRE À PARTIR DE LA MÉMOIRE 1 65535 HH:MM:SS ENTRER HAUT ENTRER HAUT AUCUN HISTORIQUE Pour ENTRER 2 65535 HH:MM:SS AUCUN HISTORIQUE 3 65535 HH:MM:SS AUCUN HISTORIQUE 4 65535 HH:MM:SS AUCUN HISTORIQUE 5 65535 HH:MM:SS AUCUN HISTORIQUE...
Page 73
Utilisation Informations relatives à l’autodiagnostic MODE DIAGNOSTIC Fréquence sortie = 50Hz MODE DIAGNOSTIC puissance d’entrée 000V / 00Hz MODE DIAGNOSTIC REDRESSEUR OK MODE DIAGNOSTIC CHARGEUR OK MODE DIAGNOSTIC BATTERIE OK MODE DIAGNOSTIC BUS CC OK MODE DIAGNOSTIC TEST ONDULEUR MODE DIAGNOSTIC ONDULEUR OK NIVEAU DE CHARGE 00.00KW / 000%...
Page 74
Utilisation Informations affichage – mode à double conversion NIVEAU DE CHARGE 00.00KW / 000% NIVEAU DE CHARGE 00.00KVA / 000% TENSION D’ENTRÉE 000V / 00.0Hz TENSION DE DÉRIVATION 000V / 00.0Hz TENSION DE SORTIE 000V / 00.0Hz CAPACITÉ DE LA BATTERIE 000V / 000% AUTONOMIE 00000 MINUTES...
Page 75
Utilisation Informations affichage – Mode dérivation NIVEAU DE CHARGE 00.00KW / 000% NIVEAU DE CHARGE 00.00KVA / 000% TENSION D’ENTRÉE 000V / 00.0Hz TENSION DE DÉRIVATION 000V / 00.0Hz TENSION DE SORTIE 000V / 00.0Hz CAPACITÉ DE LA BATTERIE 000V / 000% AUTONOMIE 00000 MINUTES À...
Page 76
Utilisation Alerte batterie Messages de surcharge SURCHARGE ! CHARGE = XXX% X.XXKW Condition de surcharge Durée du compte à rebours Messages dérivation Paramètres de la MESSAGES DE tension de dérivation L’ÉCRAN LCD >15% supérieur dérivation hors tension à la normale XXXV / XX.X HZ >20% inférieur dérivation hors tension...
Page 77
Utilisation Messages d’arrêt PARAMÈTRES MESSAGES DE D’ARRÊT L’ÉCRAN LCD Surcharge CESSER prolongée surcharge XXX% Court-circuit CESSER de sortie court-circuit O/P Commande d’arrêt à CESSER distance (Via DB9) commande à distance Commande d’arrêt à CESSER distance (Via EPO) arrêt d’urgence STOP ! CESSER Défaillances arrêt + BUS CC trop élevée...
Stockage et entretien Stockage Réparations Garantie Garantie limitée de 2 ans Numéros d’identification de conformité aux règlements L’information de conformité WEEE pour les clients de Tripp Lite et recycleurs (Union européenne) 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support...