Measurement using Flash Unit with Synchro Cord
It is recommended that the meter is used in the wired measurement mode when
the flash light is measured from subject position or when the meter fails to register
flash light from wireless measurement; for example, close to a fluorescent lamp, or
in high ambient conditions etc.
1. Set the mode selection switch to position
The symbol
the display (Fig. 10).
2.
Set the film speed (ISO) and shutter speed
as shown in the paragraph for "Preparing the
Meter for Operation".
3.
Connect the synchro cord to the synchro
terminal of meter and to the flash unit.
4.
Press the measuring switch to fire the flash. The
appropriate F-stop value is displayed on the
meter. Press the measuring switch again for
repeat measurements (Fig. 11).
Note: The notes for wireless measurement
are also applicable to wired
measurement.
will be indicated on