Conversion From Lpg To Natural Gas - Zanussi ZBG 331 User Manual

Built-in oven
Hide thumbs Also See for ZBG 331:
Table of Contents

Advertisement

Conversion from LPG to Natural Gas

IMPORTANT
The replacement/conversion of the appliance
should only be undertaken by a competent
and qualified engineer.
It is important to note that this model is designed for use
with LPG gas but can be converted for use with Natural
providing the correct injectors are fitted. The gas rate is
adjusted to suit.
Replacement of gas oven
burner injector
To replace the gas oven burner injector, follow this
procedure:
1. Remove the bottom plate of the oven ("A") to access
the gas oven burner ("B")
2. Undo the two fixing screws ("C") which keep the gas
oven burner in place
3. Gently slide the oven gas burner off the injector
support ("D") and slowly move it to the left hand side.
Check that the burner bush does not slip off the burner
mouthpiece, and take care not to cause stress to the
spark candle connection wire ("E") and the
thermocouple ("F") conductor;
3. With a 7 mm socket spanner unscrew and remove
the gas burner injector ("D"), and replace it with the
required one (see Table on this page);
4. Reassemble the burner following the same procedure
backwards.
The oven burner does not need any primary
air regulation.
Gas Oven Burner Data
GAS
INJECTOR
TYPE
MARK
1/100 mm
Natural Gas
114
(G20)
LPG
078
(G30/G31)
NOMINAL
NOMINAL GAS
GAS
FLOW IN
POWER
3
(kW)
m
/h
2,7
0,257
2,5
-
REDUCED
GAS
POWER
g/h
(kW)
-
1,0
182
1,0
BY-PASS
NOMINAL
NEEDLE
GAS
(1/100 mm)
PRESSURE
(mbar)
Reg.
20
52
28-30 / 37
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents