CLEANING AND MAINTENANCE

18
Pilot and Burner
Logs

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

CLEANING AND
MAINTENANCE
WARNING: Installation and repair should be done
by a qualified service person. The appliance should
be inspected before each use and at least annually by
a qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting,
bedding material, pet hair, etc. It is imperative that the
control compartments, burners, and circulating air
system be kept clean.
WARNING: The logs can be hot. Handle only
when cool.
WARNING: Turn off gas and electrical power
before servicing appliance.
PILOT AND BURNER
• Remove logs and ember material before cleaning burner and
replace when cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove
excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to log placement informa-
tion on page 13 to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See Replacement Parts.
• Replace ember material periodically as needed. See Replace-
ment Parts.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low if using propane/LP gas
You may feel your gas pressure is too low. If so, contact your local
gas supplier.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA's Technical Service Depart-
ment at 1-866-672-6040. When calling, please have your model and
serial numbers of your heater ready.,
You can also visit DESA's technical services web site at
www.desatech.com.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply
original replacement part(s) call DESA's Technical Service Depart-
ment at 1-866-672-6040 for referral information.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply original
replacement part(s) call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number
108660-01D