Desa P325 Owner's Operation And Installation Manual page 11

B-vent decorative gas fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
4. Connect wires to control circuit. Connect white wire to termi-
nal marked TH/TP on control valve. Connect red wire to male
blade connector provided at open end of safety circuit wiring
(see Wiring Diagram, page 29).
5. Locate the battery clip mounted on the back of the receiver
(see Figure 15).
6. Slide 9-volt battery (not included) through the clip. Note: Only
use alkaline battery.
7. Attach the terminal wires to the battery (see Figure 15).
8. Replace refractory brick access panel.
Battery
Clip
Terminal
Wires
Figure 15 - Installing Battery in Receiver
Installing 9-Volt Battery in Hand-Held Remote
Control Unit
1. Remove battery cover on back of remote control unit.
2. Attach terminal wires to the battery (not included). Place bat-
tery into the battery housing. Note: Only use alkaline battery.
3. Replace battery cover onto remote control unit.
Battery
Cover
Terminal
Wires
9-Volt
Battery
Figure 16 - Installing Battery in Hand-Held Remote Control Unit
108660-01D
Optional Wireless Hand-Held Remote Control Installation (Cont.)
9-Volt Battery
Receiver
Remote
Control Unit
Battery
Housing
For more information, visit www.desatech.com
For more information, visit www.desatech.com
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by
your gas supplier or a qualified service person.
WARNING: Before you proceed, make sure your
gas supply is OFF.
The appliance and it's individual shutoff valve must be discon-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
A manual shutoff valve has been included in the appliance's gas
supply system. You may consider installing an extra gas shutoff
valve outside the appliance's enclosure (check with local codes)
where it can be accessed more conveniently with a key through a
wall as shown in Figure 17.
In conformance with local codes, route a 1/2" NPT gas line
towards the appliance coming in from any of the 3 directions
shown in Figure 18.
CAUTION: Do not kink flexible gas line.
Typical Exterior Wall Gas
Shutoff Installation
Key
Figure 17 - Manual Shutoff Valve Installation
1/2" NPT Incoming
Black Iron Gas Line
3
8
/
"
8
7"
7"
Alternate Gas Supply
Through Sub-Floor
Figure 18 - Routing Incoming Gas Line
INSTALLATION
11
11
Gas Line Hook-Up
Shutoff
Valve
Extension
Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side
5
10
/
"
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vp324P325bVp325Vp325bP324

Table of Contents