Technical Data; Instructions For The Installer - Zanussi ZOB 231 User Information

Table of Contents

Advertisement

18 electrolux

Technical data

Heating element ratings
Bottom heating element
Top heating element
Full oven (Top+Bottom)
Grill
Fan cooking
Oven fan
Oven light
Cooling Fan
Total rating
Operating voltage (50 Hz)

Instructions for the Installer

Installation and connection must be
done in compliance with the
regulations
interventions must be carried out
when the appliance is switched off.
Only accredited engineers may work
on the appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please
make sure:
-
The fuse and the domestic electrical installation
must be designed for the max. load of the
appliance (see rating plate).
-
The domestic electrical installation must be
equipped with a proper earth connection in
accordance with the regulations in force.
-
The socket or the multi-pole off switch must be
easy to access after the appliance has been
installed.
18
1000 W
800 W
1800 W
1650 W
1825 W
25 W
25 W
25 W
1875 W
230 V
in
force.
Any
Dimensions of the recess
Height
Width
Depth
Oven
Height
Width
Depth
Oven capacity
The appliance is supplied without an electric sup-
ply cable,therefore you will have to fit to it a supply
cable with standardplug, suitable to the total elec-
tric load shown on the ratingplate. The plug is to
be inserted into a suitable wall socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit between
the appliance and the mains an omnipole switch,
with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance
with rules in force. The green & yellow ground
wire must not be interrupted by the switch, and
should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases
be laid out in such a way as to ensure that it does
not reach at any given point a temperature 50°C
higher than the ambient temperature.
Suitable power supply cables are the following
types, considering the respective necessary
section of cable: H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
under top
mm 593
in column
mm 580
mm 560
mm 550
mm 335
mm 405
mm 400
56 l