Operation - Mitsubishi Electric Mr. Slim SEZ-KD09 Operation Manual

Mr. slim
Hide thumbs Also See for Mr. Slim SEZ-KD09:
Table of Contents

Advertisement

Available languages

Available languages

5. Operation

5.1. Description of "AUTO RESTART FUNCTION"
• This unit is equipped with the auto restart function. When the main power is
turned on, the air conditioner will start operation automatically in the same
mode as set with the remote controller before the shutoff of main power.
• If the unit was set to off with the remote controller before the shutoff of
main power, it will remain stopped even after the main power is turned on.
• If the unit was in the TEST RUN before the shutoff of main power, it will
start operation, at main power on, in the same mode as set with the
remote controller before the TEST RUN.
2
3
3
TEMP.
2
MENU
BACK
MONITOR/SET
PAR-21MAA
CLOCK
5.2. Turning ON/OFF
<To Start Operation>
I Press the ON/OFF button 1.
• The ON lamp 1 and the display area come on.
Note:
G When the unit is restarted, initial settings are as follows.
Remote Controller settings
Mode
Last operation mode
Temperature setting
Last set temperature
Fan speed
Last set fan speed
<To Stop Operation>
I Press the ON/OFF button 1 again.
• The ON lamp 1 and the display area go dark.
Note:
Even if you press the ON/OFF button immediately after shutting down the op-
eration is progress, the air conditioner will not start for about three minutes.
This is to prevent the internal components from being damaged.
5.3. Mode select
I If the unit is off, press the ON/OFF button to turn it on.
• 1 The ON indicator should light up.
I Press the operation mode (
tion mode 2.
Cooling mode
s
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode
Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
Information for multi system air conditioner (Outdoor
unit: MXZ series)
s s s s s Multi system air conditioner (Outdoor unit: MXZ series) can con-
nect two or more indoor units to one outdoor unit. According to the
capacity, two or more units can operate simultaneously.
• When you try to operate two or more indoor units with one outdoor unit
simultaneously, one for the cooling and the other for heating, the opera-
tion mode of the indoor unit that operates earlier is selected. The other
indoor units that will start the operation later cannot operate, and will
KB79K741H01_en.pm6
6
4
5
8
˚F
˚F
7
ON/OFF
1
ON/OFF
FILTER
DAY
CHECK
TEST
1
OPERATION
CLEAR
5
7
8
6
) button 2 and select the opera-
5
flash the operation state.
In this case, set all the indoor units to the same operation mode.
• There might be a case that the indoor unit, which is operating in
(AUTO) mode. It cannot change over to the operating mode (COOL ↔
HEAT) and goes to stand by mode.
• When indoor unit starts the operation while the outdoor unit is in defrost
mode, it takes a few minutes (max. about 15 minutes) to blow out the
warm air.
• In heating operation, though an indoor unit that is not operating may it
get warm or the sound of refrigerant flowing may be heard, it is not mal-
functioning. That the refrigerant continuously flows into it.
Automatic operation
I According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
I During automatic operation, if the room temperature changes and re-
mains 4 °F [2 °C] or more above the set temperature for 15 minutes, the
air conditioner switches to cooling mode. If the room temperature re-
mains 4 °F [2 °C] or more below the set temperature for 15 minutes, the
air conditioner switches to heating mode.
Cooling mode
15 minutes (switches
from heating to cooling)
15 minutes (switches
from cooling to heating )
I Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).
5.4. Temperature setting
s s s s s To decrease the room temperature:
button 3 to set the desired temperature.
Press
The selected temperature is displayed 3.
• Each time you press the button, the temperature value decreases by 2 °F
[1 °C].
s s s s s To increase the room temperature:
Press
button 3 to set the desired temperature.
The selected temperature is displayed 3.
• Each time you press the button, the temperature value decreases by 2 °F
[1 °C].
• Available temperature ranges are as follows:
67 °F [19 °C] - 86 °F [30 °C]
Cooling/Drying:
63 °F [17 °C] - 83 °F [28 °C]
Heating:
67 °F [19 °C] - 83 °F [28 °C]
Automatic:
• The display flashes either 47 °F [8 °C] - 103 °F [39 °C] to inform you if
the room temperature is lower or higher than the displayed temperature.
5.5. Fan speed setting
I Press 5
button to select a desired fan speed.
• Each time you press the button, available options change with the
display 5 on the remote controller, as shown below.
Remote controller display
Fan speed
Low
Medium
M
(
)
(
)
3-stage
Note:
Auto Mode is not recommended if this indoor unit is connected to a MXZ type
outdoor unit.
08.10.7, 9:33 AM
Set temperature +4 °F [2 °C]
Set temperature
Set temperature -4 °F [2 °C]
High
Auto
(
)
5