Remote Control Handset Operation & Programming - Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System Installation And Operating Manual

Direct vent gas stove with top cooking burner system
Table of Contents

Advertisement

PILOT FLAME
ADJUSTMENT
PILOT FLAME ADJUSTMENT
The pilot flow is factory set to maximum. The pilot
flame should envelope 3/8" to 1/2" of the thermo-
couple. See the illustration above.
The adjustment screw can be reached through the
MAN-knob. See top illustration above.
1. Turn the Man-knob to the ON position.
2. It is now possible to pierce through a film on
the cover with a screwdriver to reach the adjust-
ment screw beneath.
3. Turn the adjustment screw clockwise to de-
crease or counterclockwise to increase pilot
flame.
LIGHTING AND OPERATION
CORRECT MAIN BURNER FLAMES
CORRECT PILOT FLAMES
THERMOCOUPLE FLAME
REMOTE CONTROL HANDSET
OPERATION AND PROGRAMMING
Flame Height Adjustment
"MAN"
26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fireluxe

Table of Contents