MAIN BURNER
Input Rating-Btu/hr
Min. Input-Btu/hr
Orifice-DMS
COOKING BURNER
Input Rating-Btu/hr
Min. Input-Btu/hr
Orifice-DMS
GAS SUPPLY
Manifold Pressure
Min. Supply Pressure
Max. Supply Pressure
Annual Fuel Utilization Efficiency (AFUE)
Steady State Efficiency
It is recommended that the pilot flame be turned off if the appliance will not be in use for an
extended period of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Fuel conversion kits that
include the necessary parts and instructions are available from your installer, dealer or Harman Stove Co.
This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2005 • CSA 2.33-2005
Vented Gas Fireplace Heaters and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.
The FireLuxe is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500
feet) in Canada without change. If your installation is at an elevation greater than these, consult with the
local authority having jurisdiction for gas product installations to determine their specific requirements for
high altitude installations.
28" (71cm)

SPECIFICATIONS

Natural Gas
36000
23000
#34
12000
3500
#52
4.5"w.c./1.3kPa
5.0"w.c./1.3kPa
10.0"w.c./1.8kPa
72.7%
73.4%
30 1/2" (77.5cm)
23 1/4" (59cm)
5
Propane (LP)
36000
23000
#50
12000
3500
#58
10.0"w.c./2.5kPa
11.0"w.c./2.8kPa
13.0"w.c./3.3kPa
74.9%
75.6%
20 1/2"" (52cm)