Only For Qualified Installers
Wall Mounting Brackets
Install wall mounting brackets to side of blower box with
three screws.
Blower Box
Blower
Assembly
Box Cover
Install blower box between wall studs as shown. Run 3" x
10" duct to blower box and secure. Do not use the wall
cavity as a duct.
Run wires to blower as shown in wiring diagram on page
36. Mount blower assembly in box as shown. Test blower.
Note: Blower will not run until fireplace is hot.
INSTALLATION (Options)
Register
31
Blower Cover
Mount blower cover as shown .
Install and finish drywall as desired.
Mount register after drywall and painting are finished.