Page 1
SERVICE MANUAL PARTS LIST WET / DRY VACUUM CLEANER MODELS: PV-3000 LR PV-3000 GR 120 V~ 50/60 Hz 3.4 Amp KOBLENZ ELECTRICA S.A. DE C.V. September-06 LP-VPV-200609 E-mail: thorne_scsm@koblenz-electric.com September / 2006...
Page 2
INDEX PAGE OPERATING TEST II.- REPLACEMENT PROCEDURES III.- TROUBLE SHOOTING CHART IV.- WIRING DIAGRAM VACUUM CLEANER ASSEMBLY VI.- VACUUM CLEANER PARTS LIST September / 2006...
Page 3
I.- OPERATING TEST The vacuum cleaner can work from 105 to 135 V. The current must be of 3 to 4 Amps. There should be no abnormal noise or vibration, the carbon brushes spark should be small and uniform, and the commutator must have dark brown strip and uniform.
Page 4
III.- TROUBLE SHOOTING CHART 1.- MOTOR DOES NOT RUN CAUSE SOLUTION Not firmly plugged Check attachment plug Bad on-off switch Replace Switch Line cord open Replace cord Motor Open Replace motor 2.- LOW SUCTION CAUSE SOLUTION Tank full Empty tank Hose or wand closed Clean obstruction Motor slow...
Page 6
V.- VACUUM CLEANER ASSEMBLY September / 2006...
Page 7
VI.-VACUUM CLEANER PARTS LIST PART No. DESCRIPTION PV3000 LR PV 3000 GR 28-0976-2 SWITCH ON-OFF ASSY 11-0184-9 SWITCH ON-OFF 09-1128-9 LEAD BLACK 13-2750-1 COVER DWELLED 13-2751-9 COVER GRAFFITO 13-2803-8 COVER HEAT TRANSFER 13-2243-7 COVER HANDLE DWELLED 13-2244-5 COVER HANDLE GRAFFITO 13-2799-8 COVER HANDLE 13-2250-2...
Page 8
610 Lanark Suite 205 San Antonio TX, 78218 Tel (210) 590-1226 Fax (210) 590-1258 1-800-548-5741 FACTORY Koblenz Electrica, S.A. de C.V. Av. . Ciencia No 28 Cuautitlán Izcalli Edo. de México, C.P. 54730 Tel : 5864-0300 Web site : http://www.koblenz.electric.com KOBLENZ ELÉCTRICA S.A.