Premier Series Master User Guide

Adding New Users to the System

When the control panel is first installed, only the Engineer code and the Master User
code exist, additional users need to be added to the alarm system manually.
!"
The factory default Master User code is
The Master User code is always User 01 and can never be deleted.

Programming New Users

Each User on the system is made up of the following elements. 1, 2 or 8, 3 and 4, these are
essential for the code/TAG to function correctly, items 5, 6 and 7 are optional.
1. User Number
When users are assigned to the system, they need to be identified by the control panel.
Each user is identified as Users 01, 02, 03 etc. User 01 is always the Master User.
2. User Code
This is a unique 4, 5 or 6 digit code number that is assigned to a user (the system will allow
a mixture of different lengths). The User code must be entered at a keypad to operate the
alarm system.
3. User Areas
Any number of areas can be assigned to the selected user. Assigning areas to a user
determines which areas can be armed, disarmed, reset etc. by that user. In addition,
assigning areas to a user determines which of the area related functions i.e. omitting
zones, silent arming etc. will be available to that user.
4. User Types
The User type determines which functions are available to the user i.e. arming,
disarming, resetting etc. and also, which options the user can access i.e. Setup Users,
System Tests etc.
5. User Time Lock
This option allows the selected user to be denied access to the system at different times
of the day and days of the week. When a Control Timer is assigned to a user, the User
code will not allow access to any functions during the timers 'On' period.
6. User Name Text
Each user can be assigned up to 8 characters of name text. The name text is displayed
whenever a code is entered and also when reading the log, making identification of
people using the alarm easier.
7. Door Control
This option would normally be used for access control. Users are able to open/unlock
doors that are assigned to their user code.
8. Proximity TAG
As well as or instead of operating the alarm system with a 4, 5 or 6-digit code number, it
is also possible to operate it by presenting a Proximity TAG to the keypad (this requires a
Proximity keypad).