Vector MAXX SST 3000 VEC051 Owner's Manual page 14

3000 watt continuous / 6000 watt peak converts 12 volt dc to 110 volt ac advanced mosfet technology
Table of Contents

Advertisement

APPLIANCE
LAPTOP COMPUTER
HOUSEHOLD POWER MIXER
240-WATT STEREO/AMPLIFIER
REFRIGERATOR
3/8" VARIABLE SPEED DRILL
VARIABLE SPEED JIG SAW
10-SPEED BLENDER
BELT SANDER
3/8" REVERSIBLE DRILL
HOUSEHOLD FOOD PROCESSOR
COMPUTER AND MONITOR
PORTABLE VACUUM
8-CUP COFFEE MAKER
ELECTRIC TRIMMER
1/2" HAMMER-DRILL
RECIPROCATING SAW
VACUUM CLEANER
1-1/8" ROTARY HAMMER
1/6 H.P. SUBMERSIBLE SUMP PUMP
COMPACT MICROWAVE OVEN
2-SLICE TOASTER
HEAVY-DUTY WORKLIGHT
14" CHAIN SAW
42" FAN
200 MPH BLOWER/VAC
16" CHAIN SAW
WET-DRY VAC, 6 H.P., 16 GALLONS
10" BENCH SAW
FULL-SIZE MICROWAVE OVEN
12" COMPOUND MITER SAW
12-1/2" PORTABLE PLANER
HEAVY-DUTY 7-1/4" CIRCULAR SAW
14" CHOP SAW
NOTE: APPLIANCE SPECIFICATIONS MAY VARY FROM BRAND TO BRAND. THIS TABLE IS OFFERED
ONLY AS A GUIDE TO APPROXIMATE POWER RATINGS. CHECK APPLIANCE MANUALS OR
PRODUCT LABELING FOR ACTUAL RATINGS.
AMPS@110VAC
WATTS@110VAC
0.5
55
2
240
2.2
265
3
360
3
360
3
360
3.2
375
3.4
410
3.5
420
3.6
430
4
450
4.6
540
5.5
650
5.5
660
5.5
660
6
720
7.2
865
7.8
940
8
960
8.5
1020
8.8
1050
9
1080
10
1200
10.3
1235
12
1440
12
1440
12
1440
13
1560
14.5
1750
15
1800
15
1800
15
1800
15
1800
11
Low Battery Alarm:
An audible alarm will sound when:
1. The 12 VDC power supply voltage drops down to 10.6 volts. This indicates
that the power source (battery) needs to be recharged, or there is an excessive
voltage drop between the battery power source and the inverter.
2. The inverter is overloaded.
3. The inverter is in thermal shutdown.
NOTE: It is normal for the alarm to sound when the
connected to, or disconnected from, a 12 VDC power source. This does
NOT indicate a problem. However, if this alarm is heard, except as
described, discontinue inverter operation and recharge the battery before
further use. If the voltage drops to 10.0 VDC, the inverter will automatically
shut down. The inverter will automatically restart when the input voltage
increases.
If the low voltage alarm sounds when the battery power source is fully charged,
refer to the troubleshooting table for possible causes and remedies.
4.4.4
Circuit Protection
The inverter has electronic circuit protection. The two front panel mounted 15 amp circuit
breakers can be manually reset in the event they trip due to an overload or short circuit
condition. If the High Output Terminal Block is used, a user-supplied dual ganged
30 ampere circuit breaker MUST be wired to protect the external wiring and
devices connected to it.
WARNING
The inverter is an industrial grade, heavy duty device that generates high voltage.
The front-panel mounted circuit breakers handle any overload situations by dis-
connecting AC output to prevent potential damage to the inverter and/or any
equipment that it is powering. If re-setting the front-panel mounted circuit breakers
or the external mounted hardwire circuit breaker does not cure a problem, DO
NOT ATTEMPT TO OPEN THE INVERTER. Opening the inverter, for any reason,
will void the warranty. The unit must be returned to Vector Manufacturing, Ltd. for
testing and repair by professional factory technicians.
3000
MAXXSST
16
is being

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxxsst 2200Maxxsst 3000

Table of Contents