Start Up; Testing The Installation - Sundance Spas Spas Installation Instructions Manual

Spa equipment system
Table of Contents

Advertisement

To install the remote freeze sensor, secure the sensor to the pipe
where the temperature is to be sensed using plastic tie straps. If
needed, the wire may be lengthened by splicing-in additional
wire making certain that the splices are tight. The wire must be
protected to ensure that it cannot be accidentally disconnected
or broken. Run the connector through an opening in the bottom
of the control box and plug it into the JP20 connection on the
Sentry circuit board (Ill. 1, item 12).
To test the remote freeze sensor, place an ice cube on it before
strapping it on the pipe. Both pumps should come on within a
minute or two. IMPORTANT: Do not perform this test unless
the spa is full of water and the spa installation is fully
operational.

Start Up

Follow the start up instructions in the " Owner Operating
Instructions" supplied with this equipment system.
13

Testing the Installation

Once the installation is complete, but prior to filling in the
trenches or decking around the spa, the installation should be