  • Page 1 MX SERIES MXA2080 Power Amplifier Owner’s Manual...
  • Page 2: Table Of Contents

    THE AC POWER CORD. ALLOW allows remote control of standby and mute Protection and Muting SUFFICIENT TIME FOR COMPLETE functions. In addition to this, the MXA2080 EVAPORATION TO OCCUR BEFORE may be switched into or out of standby Fault Condition Indication OPERATING THE UNIT AGAIN.
  • Page 3: Power Inlet

    STANDBY, then switching the preamplifier amplifier Plug the female (socket) end of the power out of standby will also bring the MXA2080 or multi-room systems may be built. cord into the power inlet on the rear of the out of standby. In this way an MXP2000 + amplifier.
  • Page 4: Remote Trigger Control Input/Output

    7. Remote Trigger Control input/output If the MXA2080 is being used in a system without a Myryad preamplifier, processor or integrated equipped with My-Link, the REMOTE TRIGGER input may be used to allow the MXA2080 to be remotely switched into or out of STANDBY.
  • Page 5: Front Panel Controls

    This is normal and no cause for concern. CAUTION: WHEN IN STANDBY MODE THE INTERNAL CIRCUITRY OF THE MXA2080 IS STILL LIVE, SO ALL SAFETY PRECAUTIONS MUST BE FOLLOWED 2. Loudspeaker output protection and muting When the amplifier is in standby mode the loudspeaker output terminals are isolated from the amplifier by high quality relays.
  • Page 6: Fault Condition Indication

    Left channel fault INDICATION Right channel fault This display will appear for about 2 Each of the MXA2080’s power amplifier seconds, after which it will alternate with the channels has an intelligent loudspeaker “Fault type” display. The displays will protection system. If a fault occurs in either...
  • Page 7: Trouble-Shooting Guide

    No sound from one channel only: Amplifier fails to respond to Smart My Link® remote commands from Myryad TROUBLE- Loudspeaker cable pulled loose. Preamplifier, Preamp-Processor or Check all connections, both at the Integrated: SHOOTING GUIDE loudspeakers and amplifier. Interconnect cable pulled loose or My-Link cable is loose or not making poor contact.
  • Page 8 Myryad Systems Ltd. 2 Pipers Wood, Waterberry Drive Waterlooville, Hants, PO7 7XU Tel: +44 (0) 23 9226 5508 Fax: +44 (0) 23 9223 1407 info@myryad.co.uk www.myryad.co.uk For further information, Please contact Myryad direct or visit: www.myryad.co.uk Stock No: 0ST0012400 A...