Wired remote control

f If an error occurs,
is displayed on the wired remote control.
If you would like to see an error code, press the Test button.
Display
Explanation
Remark
Indoor unit Communication Error
Indoor/Outdoor unit Communication Time Out Error
60 Packet Over data
Communication Error
Indoor unit is not connected
Communication Error between Outdoor Main and Inverter Micom (Occurred
after 1 minute detection in Main and Inverter)
Indoor Temp. Sensor (Open/Short Error)
Indoor Unit Eva in Sensor (Open/Short Error)
Indoor Sensor Error
Indoor Unit Eva in Sensor Separation
Outdoor Temp. Sensor Error (Open/Short Error)
COND Temp. Sensor Error (Open/Short Error)
Outdoor Sensor Error
Inverter Compressor Discharge Temp. sensor Error
(Open/Short Error)
Power cable miss connection error
Indoor Float S/W 2
Detection
nd
Outdoor unit - indoor unit communication wire miss connection (Connected
to Power terminal)
Self Diagnosys Error
Outdoor unit refrigerant Full leakage (Gas leak)
Outdoor Fan 1 Error
Outdoor Fan 2 Error
Discharge over temperature
[Inverter] Compressor starting error
Primary Current Over Trip error
[Inverter] DC PEAK error(O.C)
[Inverter] Compressor Rotation error
Outdoor Unit Protection
Control Error
[Inverter] Current Sensor error
[Inverter] DC LINK Sensor error
[Inverter] EEPROM Read/Write Error
[Inverter] Heatsink temperature over Error
Outdoor unit Capacity Setup option error
Communication error between Indoor unit and wired remote control
Communication error between Master and Slave wired remote control
Wired Remote Control Error
COM1/COM2 Cross-installed error
Error of setting option for wired remote control COM2