LOCATION OF APPLIANCE

For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas Installation IS813
Current Edition Section 7 Permitted locations of appliance Table 4---Locations and Permanent Ventilation
requirements-flueless appliances.
This appliance must not be installed in a bed-sitting room of volume less than 20m³ or in a bathroom, shower
room or garage. It is essential that the appliance is positioned as stated below (see Fig. 1a) i.e. shelves, wall
cabinets and cooker hoods must be fitted a minimum of 787mm directly above the top of hotplate and 400mm
above the hotplate when fitted in line with the outside of the appliance. If the units are intended to be fitted
adjacent to the appliance but less than 400mm above the hotplate, then a minimum space of 100mm must be
maintained between the sides of the unit and the appliance (see Fig.1b). Curtains must not be fitted
immediately behind the appliance or within 150mm of the sides of the hotplate. If fitted next to or between two
base units a minimum space of 1mm must be left between each unit and the sides of the appliance. The
levelling feet fitted to the appliance will achieve a nominal height to hotplate trims of 900mm +20mm.
L.P.G. cookers MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or
other vessel.