Installation
Turn the water off at the supply
before beginning this installation.
Remove the covers from the plaster shields (1).
Trim the plaster shields so that they extend
1/16" outside the surface of the finished wall
().
Seal the wall around the plaster
shields with waterproof sealant.
Failure to seal the wall can lead
to possible water damage.
Use a 17 mm socket wrench to remove the
spout plug.
Use a 7 mm socket wrench to remove the
cartridge housing.
Remove and discard the flush insert.
Lightly grease the cartridge o-ring using the
enclosed lubricant.
Install the cartridge and anti-twist device in the
housing.
2.
1.
17 mm
7 mm
3