Page 1
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Rev.1.0 (April 2011) Website: www.Veilux.net Phone# 1-800-510-6528...
Page 2
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Certification Veilux provides the best products with the certification below. Revision History Date Rev No. Description 2010-11 Creation of the document Rev.1.0 (April 2011) Website: www.Veilux.net...
Page 3
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Warning & Cautions If you fail to read this information and handle the product incorrectly, faulty or malfunction as well as death or serious injury may occur.
Page 4
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Indications: Warning: Death or Serious Injury will occur without following Warning. Caution : Operational Problem(Faulty & Malfunction) will occur without complying with Caution Reference : Technical Information for Users Rev.1.0 (April 2011)
D= Outdoor 1. Introduction Veilux VPIP-D1XXX-O / VPIP-D1XXX-I, as a state-of-the-art 1Channel Speed Dome Network Camera based on integrated Embedded Software technologies such as H.264 & MJPEG, G.726 & PCM Video & Audio Compression, Embedded Web Server, Embedded Streaming Server, various Network Protocols, transmits...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Class Description Compression H.264 / MJPEG Video Resolution **Refer to the datasheet Audio Up Stream 32 Kbps G.726 (Bi-directional) Down Stream 64 Kbps PCM...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Management Sync to Time Server Internet Time Server Summer Time Configuration Class Description Image Size 6mm Dia. (Type 1/3) CCD Image Effective Pixels 1.3M (1296 x 966)
Page 13
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Resolution Horizontal 600 TVL (1280 x 720 pixels) Min. Sensitivity IR-cut On (1/30s) 1.8 Lux (F1.6, 50IRE) IR-cut Off (1/4s) 0.02 Lux Rev.1.0 (April 2011) Website: www.Veilux.net...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 2. Production Description Open the package and check if the followings are included; Contents Description Remark Bracket & Housing Outdoor Housing, Wall Mount Bracket...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Veilux VPIP-D1XXX-O / VPIP- CMS Software IP-Installer D1XXX-I (NVXR-64) PC based Client for monitoring/storing Video/Audio Speed Dome Network Camera IP Assignment Program transmitted form Product (Max.
100Base-T 100Mbps Ethernet connector (RJ-45). 2 LEDs on the Ethernet connector shows the status of Veilux VPIP- D1XXX-O / VPIP-D1XXX-I as the followings: Status LED (Dual Color - Red/Green): It will be lit in green or red depending on the status.
Page 20
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Alarm In/Out (ALARM/AUX) Used for connecting alarm sensor, alarm annunciation device to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I. Class Description Alarm IN Sensor In (+). NC/NO Selectable in Admin Mode...
Page 21
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Photo Coupler NO/NCType Open CollectorType Sensor1+ Sensor Sensor Device Device Sensor1- +12V Sensor Sensor Power Power Supply Supply Fig 2-6. Sensor Input Connection Diagram Rev.1.0 (April 2011)
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 3. Bracket Installation 3.1. Veilux VPIP(MP) & & 1. Open the Dome Cover by unscrewing with wrench. Rev.1.0 (April 2011) Website: www.Veilux.net Phone# 1-800-510-6528...
Page 23
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 2. Configure the DIP Switch by referring Appendix. When using system controller for the control of the dome, always set the RS-485 communication channel to be : 2400 bps, 8 bit, 1 stop bit, no parity.
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor The wall should be strong enough to hold 4 times of the weight of the camera (5.3 KG). This means that the wall should withstand weight of 21.2 KGs in the minimum.
Page 25
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Hidden Cable Exposed Cable 3. Connect Sun-Visor with Wall Mounting Bracket. (1) 4. After connecting Product and Cable, install the product by inserting Product into internal fixing hole of housing and turning in clockwise.
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 3.2 Veilux VPIPI(MP) 1. Open the Dome Cover by unscrewing with wrench. 2. Configure the DIP Switch by referring Appendix. When using system controller for the control of the dome, always set the RS-485 communication channel to be : 2400 bps, 8 bit, 1 stop bit, no parity.
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 3. Place the Dome Cover and screw. Ceiling board should be strong enough to hold the weight of approx.. 2Kg. Rev.1.0 (April 2011) Website: www.Veilux.net...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 1. Prepare 190mm Diameter Hole on the ceiling. 2. Place Safety Wire between suspension and Safety Ire Hole to prevent falling-off. 3. Fold the Lock Lever and insert the bracket into the ceiling whole.
Page 29
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Prepare 190mm Diameter Hole on the Place Safety Wire between suspensions Ceiling. and Safety Wire Hole to prevent falling- off. Fold the Lock Lever and insert the Bracket into the Ceiling Hole.
Page 30
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Rev.1.0 (April 2011) Website: www.Veilux.net Phone# 1-800-510-6528...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 4. Installation Required Specification of PC for Camera Configuration & Control. Class Recommendation Remark Pentium-4 3Ghz Graphic Card Higher than ATI Chip-Set based 64M...
I= Indoor D= Outdoor Fig 4-1. LAN Cable Connection Diagram 1. Connect PC and Veilux VPIP-D1XXX-O / VPIP-D1XXX-I to Network Device(HUB) Prepare a PC which needs to be connected to Network. Connect PC (or Lab-Top) with Product as Fig 4-1.
Page 33
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor If you click each field of ③, you can use sort function. For the detail, refer to IP Installer Manual. You can select the most appropriate LAN, ADSL, Static / Dynamic IP per Cable to user’s circumstance via ⑤...
Page 34
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Web View is the simplest method to connect to product via internet explorer. Once you insert ”http://IP_address:HTTP_port_number” into Internet Explorer, you can access to the relevant product.
Page 35
4. Initial Configuration by connecting Admin Mode All Parameters of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I is initially set as factory default. So you must change them with appropriate value to your network configuration by accessing via Admin Tool. Admin Tool Access Method is as below.
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 5. Trouble Shooting Network Connection Status Check(Ping Test) You can check the Network Connection Status by doing Ping Test. - Start > Run > cmd > Ping IP Address (EX>ping 172.16.42.51).
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor & & For the use of Video Recording & Capture function on NVR-Pro and Web Viewer, Windows Vista and Windows 7 Users are required to configure “User Account Configuration” and “Program Execution Entitlement Configuration”.
Page 38
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Windows 7 Configuration 1. User Account Configuration 1) Select “User Account” on Control Panel 2) Select “Change User Account Control Setting” 3) Set the Alarm Level at the lowest “Never Notify”...
Page 39
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 2. Program Execution Entitlement Configuration 1) Select “NVXR-64” icon on the wallpaper 2) Select “Properties” menu popped up by clicking right button on Mouse 3) Select Check Box of “Run this program as an administrator”...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor Please contact to your supplier if you still have problem even taking all trouble shootings. For the quickest solution, please prepare all information below;...
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 6. Appendix 6.1. FAN & Heater FAN & Heater is inside Housing of Outdoor Speed Dome and will operate with AC24V. Cablings for the Fan & Heater are completed in the Factory .
Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O, D136X-I/O, D136X With WDR-I/O, D137X-I/O I= Indoor D= Outdoor 6.2. DIP Switch Setting A. ID Configuration * Factory Default: Camera ID = 1 (1-ON, 0-OFF) DIP SW ID VALUE DIP SW ID VALUE...