13. Install a VRM in the connector by microprocessor socket 2 (see "System-board
14. Reinstall the air baffle (see "Installing the air baffle" on page 51).
15. Close the power-supply cage (see "Closing the power-supply cage" on page
16. Reinstall the hot-swap power supplies.
17. Reinstall the left-side cover.
18. Reconnect the external cables and power cords.
If you have other optional devices to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 76.

Thermal grease

The thermal grease must be replaced whenever the heat sink has been removed
from the top of the microprocessor and is going to be reused or when debris is
found in the grease.
e. Press down firmly on the front of the heat sink until it is seated securely.
f. Rotate the heat-sink release lever to the closed position and hook it
underneath the lock tab.
internal connectors" on page 25 for the VRM connector location).
a. Open the retaining clips on each end of the VRM connector.
b. Turn the VRM so that the keys align with the connector.
c. Insert the VRM into the connector by aligning the edges of the VRM with
the slots at the end of the VRM connector. Firmly press the VRM straight
down into the connector by applying pressure on both ends of the VRM
simultaneously. The retaining clips snap into the locked position when the
VRM is seated in the connector.
44).
Chapter 5. Installing optional devices and replacing customer replaceable units
73