Installation
Requirements
Before
You InstalL.°
ElectricaJ Requirements
Gas
Exhaust
Description
Use dimensions shown in manuaU to determine space needed for instaflation,
PUace dryer on a solid floor in an area with an adequate air suppUy,A closet door
must have a suppUy air vent of 80 sq, in, (517 sq, cm) minimum,
No other fueU burning appliance shouUd be instafled in the same closet with the dryer,
Dryer must not be instafled or stored in an area where it wHU be exposed to water
and/or weather,
Manufactured
(mobile)
home installation
must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 32-80 or Standard
CAN/CSA-Z240
MH,
Gas dryers must be permanently attached to the floor at the time of installation,
Order No, 526P3 Dryer Installation Kit for a manufactured (mobile) home installation,
Dryer requires 120 volt, 15 amp, 60 Hz power supply and 3-prong
grounding
p_ug.
Power cord is approximately 69" long, Do not operate other appliances on the same
circuit when this appliance is operating, Refer to serial plate for specific require-
ments, Wiring diagram is located in control hood,
Natural Gas Pressure, 1000 Btu/fP (37,3 MJ/m3), service must be supplied at 6,5 +
1,5 inch water column pressure, L,R (propane) Gas Pressure, 2,500 Btu/fP (93,1
MJ/m3), service must be supplied at 10 + 1,5 inch water column pressure,
NOTE: The dryer and its appliance main gas valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psi (3,45 kPa), Dryer must be isolated from the gas supply piping
system by closing the equipment shut-off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 psi (3,45 kPa),
When connecting to a gas line, an equipment shutoff valve must be installed within
6' (1,8 m) of the dryer, An 1/8" N,P,T, pipe plug must be installed,
The gas service to a gas dryer must conform with the local codes and ordances or in
the absence of local codes and ordinances, with the latest edition of the National
Fuel Gas Code ANSIZ223,1/NFPA
54 or the CAN/CGA-B149,
National Gas
Installation Code, LPK1 Sales Accessory (L,R/Propane
Gas Conversion Kit 649P3)
must be installed, DO NOT connect dryer to L,P,/Propane Gas Service without
converting the gas valve,
Use rigid or semi-rigid duct and exhaust the dryer to the outside by the shortest
route possible. Failure to exhaust dryer properly will void warranty.
o Dryer exhaust duct must be secured to the mobile home structure. Dryer exhaust
MUST NOT terminate under the mobile home.
Exhaust duct must not be connected to any other duct, vent or chimney.
Venting materials are not supplied with the dryer (obtain locally). Do not use plas-
tic or thin foil flexible ducting.
Static pressure in the dryer's exhaust duct should be no greater than .6 inches (1.5
cm). Check with dryer running and no load. This can be measured with a manome-
ter placed on the exhaust duct approximately two feet (61 cm) from the dryer.
For the best exhaust system:
Locate dryer so exhaust duct is as short as possible.
Verify old ducts are cleaned before installing new dryer.
,_ Use 4 inch (10.2 cm) diameter rigid or flexible metal duct.
Use duct tape on all joints.
Use as few elbows as possible.
5